Dimensions

Note: 1. All units are in millimeters unless otherwise indicated.

2.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

3.There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application.

Switches

D4BL-@@@@-@

Four, M3.5 head clamping screws

 

 

 

(116.5)

 

31.5

Red

10

 

17

 

 

 

 

 

 

 

 

 

15

7

 

 

 

 

Lock

 

 

34.2

 

 

 

 

 

 

 

 

 

 

 

 

protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cap

 

(123.5)

 

 

 

 

 

Four, 5.3 dia.

 

 

 

 

 

 

mounting

 

 

 

 

 

 

 

 

 

74±0.1

 

 

 

 

holes

 

 

 

 

 

 

 

 

Four, M4

 

 

 

 

 

 

 

 

cover

 

 

 

 

 

 

 

 

clamping

 

6.8

 

 

 

 

 

screws

 

 

 

 

 

 

Cover

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.5

16

Conduit opening

100±0.1

 

 

 

 

 

+1

 

 

39.6

 

 

 

 

1120

 

 

Indicators

Conduit opening

37.5

86+10

Safety Door Switches D4BL

Operating Characteristics

D4BL-@@@@

Key insertion force

19.61 N max.

Key extraction force

19.61 N max.

 

 

Movement before being locked

15 mm max.

 

 

 

 

Four, M3.5 head

 

D4BL-2GRD-AT

 

clamping screws

 

(116.5)

 

31.5

 

10

 

 

17

 

 

 

 

Indicator

 

7

 

 

37.5

34.2

(Green:

 

 

 

 

Solenoid ON).

 

 

 

Four, 5.3 dia.

 

(123.5)

Mounting

 

74±0.1

holes

86+10

Four, M4

 

cover

 

 

clamping

 

 

screws

 

6.8

 

Cover

 

 

 

 

 

 

 

100±0.1

5.5

16

Conduit opening

Conduit opening

112+10

 

39.6

 

 

 

Indictor

Conduit opening

42.6

 

 

 

 

 

(Orange: Switch OFF)

 

 

 

Operating Characteristics

D4BL-2GRD-AT

 

 

Key insertion force

19.61 N max.

Key extraction force

19.61 N max.

 

 

Movement before being locked

15 mm max.

 

 

Guard Lock Safety-door Switch D4BL

A-75

Page 9
Image 9