VI. General Assembly Instructions (Cont.)
7. Set up Fan/Blower
Square
CAUTION
All moving parts must have guards to protect personnel. Safety requirements vary, so the number and type of guards needed to meet company, local and OSHA standards must be determined and specified by the user. Never start a fan without having all safety guards installed. Check regularly for damaged or missing guards and do not operate any fan with guards removed. Fans can also become dangerous because of potential windmilling, even though all electrical power is disconnected. Always block the rotating assembly before working on any moving parts.
Fan Outlet - Connect to Plenum Box
to
Round
Fan
Inlet -
Connect
to top of
Cyclone
Fan Outlet - Square to round transition for fan outlet does not come with installation hardware. Drill holes, bolt screw, or pop rivet to fan outlet, seal with silicone. Make sure pulley cover and shaft guard are in place before operation.
8.If applicable, connect silencer to
9.Connect ductwork from fan inlet to top of Cyclone Barrel.
10.Set up Plenums according to height requirements for type.
- Instructions for Cartridge Filters
Clamp filter cartridges to plenum, then clamp dust bins to cartridges.
External Filter Cartridge Cleaning Intervals
Silencer
Square
to
Round
Cartridge
Filters
When unit is turned off, use compressed air to blow dust off from exterior of filter. Hold nozzle at least 8” away from filter pleats*. Do not remove bottom dust pan before or during the
- Instructions for Tube Filters - See next page.
- Instructions for build your own plenum - See next page.
11. Connect ductwork between Fan/Blower outlet or Silencer and plenum.
10