III. General Specifications & Fan Performance Curves

1973 CFM @ 2” SP w/c w/o filter

Full 16 gauge galvanized cyclone & 14 ga. barrel

Rectangular inlet with included Square to Round to 8”

Rectangular outlet

Cast aluminum fan wheel

back inclined non-sparking, non-ferrous dynamic, two-planed balanced to ISO 6.3 specifications.

Sound 80 - 82dB @ 10’ with Built-in Silencer and Filter

130 Sq. Ft. Filter Media / Spun-Bonded

U.S. Made Baldor / TEFC / Class F / 1.15 SF

Single Phase

Three Phase

5hp Motor

5hp Motor

208 - 230V

208 - 230 / 460V

19.8A

13.6 - 12.4 / 6.2A

System Fan Curve

Pro Series 2000

Static pressure and volume together determine a fan’s performance. Several factors, such as layout of ductwork and diameter of openings, can affect a fan’s performance.

Static Pressure at Cyclone Inlet

12

 

 

 

 

 

12

 

10

 

 

 

 

 

10

 

 

11.1

 

 

 

 

 

 

CFM

SP @

8.1

 

8

w/o Filter

Inlet

 

 

1973

2.00

 

 

 

 

5.8

6

1802

2.75

 

 

 

 

1709

4.00

 

4

 

1543

5.80

 

4

 

 

1273

8.10

 

2.75

 

 

 

987

10.00

- With Filter

2

2

736

11.10

- Without Filter

 

 

0

12.00

*Fan curves vary slightly with different filter packages.

 

0

 

 

 

 

 

 

 

0 200 400 600 800 1000 1200 1400 1600 1800 2000

CFM

4

 

Pro 2000 Owner’s Manual c O.A.S. 2007

Page 5
Image 5