ACCESSORIES & TROUBLESHOOTING

ACCESSORIES & TROUBLESHOOTING

CALL CUSTOMER SERVICE HOT LINE

USA:1-800-989-3535 Canada: 1-888-676-7325

Whenever calling, please be sure to have your model from the data plate.

Accessories (Sold Separately)

ITEM

 

PART #

1.

Pre-Filter

7780-8041

2.

Ionizer/Electronic Collector Cell

09-5510-7065

3.

Charcoal Odor Absorber (Set of 4)

AT4PK7

4.

Wall Mounting Kit

8660-0201

5.Oreck Fresh Air® Scent Cartridges

Spring Mulberries®, 8pk.

FA2PK

Blooming Jasmine®, 8pk.

FA3PK

USA: 1-800-989-3535

Canada: 1-888-676-7325

Outside the USA and Canada,

contact your local Oreck Distributor.

Troubleshooting Guide

Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing the chart below. It pinpoints problems and how to correct them. Remember, check the simple things first.

PROBLEM

CHECK

 

WHAT TO DO

UNIT DOES NOT TURN

 

1. Power Cord

1.

Plug in power cord

ON

2. Selector Switch

2.

Set selector switch

 

 

 

 

for desired blower

 

 

 

 

speed.

 

 

3. Front Grill

3.

Reinsert front grill

 

 

 

 

until it is flush with

 

 

 

 

cabinet front. Tap

 

 

 

 

grill lightly, if

 

 

 

 

necessary, to fully

 

 

 

 

insert.

INDICATOR LIGHT ON

Ionizer/Electronic

Wash Collector Cell.

UNIT IS FLASHING RED

Collector Cell

Make sure it is

OR HAS TURNED RED

 

thoroughly clean & dry

 

before re-installing it.

 

 

 

RED INDICATOR LIGHT

Ionizer/Electronic

1.

Collector Cell may

WILL NOT TURN OFF

Collector Cell

 

not be completely

 

 

 

 

dry.

 

 

 

2.

Cell may be

 

 

 

 

damaged with a

 

 

 

 

broken wire.

 

 

 

3.

The “Dirty Cell”

 

 

 

 

sensor may not be

 

 

 

working correctly.

 

 

 

4. If you believe the

 

 

 

 

Collector Cell is

 

 

 

 

damaged or the unit

 

 

 

 

is not working

 

 

 

 

correctly, return the

 

 

 

 

unit to the Service

 

 

 

 

Center.

UNIT DOES NOT

Ionizer/Electronic

Wash Collector Cell.

REMOVE POLLUTANTS

Collector Cell

Make sure it is

 

 

 

thoroughly clean & dry

 

 

 

before re-installing it.

UNIT SPARKS,

Ionizer/Electronic

1.

Sparking or

CRACKLES AND POPS

Collector Cell

 

popping noise

 

 

 

 

occurs when a

 

 

 

 

large particle is

 

 

 

 

captured in the

 

 

 

 

Collector Cell.

 

 

 

2. If the unit is arcing

 

 

 

 

excessively, the

 

 

 

 

Cell may be dirty.

 

 

 

 

Try cleaning the

 

 

 

 

Collector Cell.

 

 

 

3.

If excessive

 

 

 

 

arcing continues

 

 

 

 

after proper cleaning,

 

 

 

 

the Collector Cell

 

 

 

 

may be damaged

 

 

 

 

or wet. Return unit

 

 

 

 

to the Service

 

 

 

 

Center.

DOES NOT REMOVE

Old Charcoal Odor

Replace Charcoal

ODOR

Absorber

Odor Absorber.

 

 

 

 

UNIT STILL DOES NOT

Check all the above

Return unit to the

OPERATE PROPERLY

points

Service Center.

 

 

 

 

 

ALL OTHER SERVICING SHOULD BE DONE BY AN ORECK AUTHORIZED SERVICE CENTER.