Oregon Scientific DP200 user manual Atomic Daylight Projection Clock with Outdoor Temperature

Models: DP200 DP200A

1 2
Download 2 pages 11 Kb
Page 1
Image 1
Atomic Daylight Projection Clock with

Atomic Daylight Projection Clock with

Outdoor Temperature

Model: DP200 / DP200A

USER MANUAL

EN

OVERVIEW

FRONT VIEW

1

REMOTE SENSOR

1.LED status indicator

2.Wall mount hole

3.Battery compartment

4.RESET hole

5.CHANNEL switch

STRONG

WEAK SIGNAL

NO SIGNAL

SIGNAL

 

 

 

 

 

MANUALLY SET CLOCK

To set the clock manually, disable the signal reception

rst.

1.Press and hold SET CLOCK.

2.Press Model: DP200 / DP200A or USER MANUAL to change the settings.

3.Press SET CLOCK to confi rm.

4.The settings order is: time zone offset, 12/24 hr format, hour and minute.

DP200: Time zone offset sets the clock +/- 23 hours from the received clock signal time.

Do not cover the ventilation holes with any items such

 

as newspapers, curtains etc.

Do not immerse the unit in water. If you spill liquid over

 

it, dry it immediately with a soft, lint-free cloth.

Do not clean the unit with abrasive or corrosive

 

materials.

Do not tamper with the unit’s internal components.

 

This invalidates the warranty.

Only use fresh batteries. Do not mix new and old

 

batteries.

Images shown in this manual may differ from the actual

 

display.

When disposing of this product, ensure it is collected

 

separately for special treatment.

Placement of this product on certain types of wood

 

may result in damage to its fi nish for which Oregon

 

Scientifi c will not be responsible. Consult the furniture

 

manufacturer's care instructions for information.

The contents of this manual may not be reproduced

 

without the permission of the manufacturer.

receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientifi c.com or on the warranty card for this product) for all inquiries instead.

We

Name:

Oregon Scientifi c, Inc.

Address:

19861 SW 95th Ave.,Tualatin,Oregon

 

97062 USA

Telephone No.: 1-800-853-8883

declare that the product

Product No.:

DP200 / DP200A

Horloge Radio-Pilotée Avec Projection

de jour et Température Extérieure

Modèle: DP200 / DP200A

MANUEL DE L’UTILISATEUR

FR

VUE D’ENSEMBLE

FACE SUPÉRIEURE / AVANT ECRAN LCD

1

2

3

4

11

SONDE SANS FIL

1.Indicateur LED

2.Trou de fi xation murale

3.Compartiment des piles

4.Fente RESET (Réinitialiser)

5.Bouton CHANNEL (Canal)

Signal WWVB-60 : dans un rayon de 3200 km (2000 miles) de Fort Collins, Colorado.

Activer / désactiver la réception du signal :

Maintenez le bouton pour activer ou pour désactiver le signal de réception.

REMARQUE La réception prend de 2 à 10 minutes.

Indicateur de réception du signal de l’Horloge :

SIGNAL FORT

SIGNAL FAIBLE

AUCUN SIGNAL

 

 

 

RÉGLER MANUELLEMENT L’HORLOGE

Pour régler manuellement l’horloge, vous devez tout d’abord, désactiver la réception du signal.

2

3

4

11

5

6

7

8

9

10

1.IR motion sensors (at the top): Snooze; change display mode

2.ALARM ON / OFF (at the top): Enable / disable alarm

3.Time zone

4.Clock signal reception indicator

5.Clock, alarm and temperature display

6.°C / °F temperature unit display

7.Alarm icon

8.Outdoor temperature icon

9.Battery low indicator

10.Indoor temperature icon

11.Projector: Project time,alarm status and indoor / outdoor temperature

BACK VIEW

1.FOCUS: Focus the projected image

2.Adaptor socket

3.Battery compartment

4.EU / UK: Select clock reception

5.PROJECTION AUTO / CLOCK / OFF: Select the projection mode

6.180° ROTATION: Rotate projection image by 180° degrees

7.SET ALARM: Set alarm

8.SET CLOCK: Enter clock setting mode

9.°C / °F: Select temperature unit

10./ : Increase / decrease settings; activate / deactivate clock reception signal

11.RESET: Reset unit to default settings

DP200 USA IM R2.indd 1

GETTING STARTED

POWER SUPPLY

Batteries serve as back up. For continuous use of projector and backlight, always plug in the adapter socket. Make sure the socket outlet is easily accessible to the unit.

To insert batteries:

1.Remove the battery compartment and insert the batteries, matching the polarities.

2.Press RESET after each battery change.

Horloge Radio-Pilotée Avec Projection indicates main unit batteries are low.

REMOTE SENSOR

To set up the sensor:

1.Open the battery compartment.

2.Select a channel then press RESET.

3.Close the battery door.

4.Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount .

TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.

SENSOR DATA TRANSMISSION

The main unit will automatically search for the outdoor sensor. The sensor reception icon in the remote sensor area shows the status:

ICON

DESCRIPTION

 

 

 

Main unit is searching

 

for sensor(s).

 

A channel has been

 

found.

 

Sensor 1 data

 

received.

and --.-

The sensor cannot

be found.

NOTE If the sensor is not found, check the batteries, obstructions and remote sensor location.

For best results:

Place the sensor out of direct sunlight and rain.

Position the sensor facing the main unit, minimizing obstructions.

Place the sensor in a location away from metallic or electronic objects.

Position the sensor closer to the main unit during cold winter months.

CLOCK

CLOCK RECEPTION

This product is designed to synchronize its clock automatically with a clock signal.

DP200:

Slide EU / UK to select the signal received.

EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany.

UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England.

DP200A:

WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado.

To enable / disable signal reception:

Press and hold de jour et Température Extérieure to enable or MANUEL DE L’UTILISATEUR to disable signal reception.

NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal.

Clock signal reception indicator:

LCD DISPLAY

Wave your hand at least 3 inches above the IR motion sensors to toggle display modes between:

Clock

Alarm

Outdoor temperature

Indoor temperature

ALARM

To set the alarm:

1.Press and hold SET ALARM.

2.Press Manual background / Manual background to set hour / minute.

3.Press SET ALARM to confi rm.Manual background indicates alarm is ON.

To toggle alarms ON / OFF:

1.Press SET ALARM to display alarm time.

2.Press ALARM ON / OFF to turn alarm ON / OFF.

To silence the alarm:

Wave your hand above the IR motion sensors to

silence it for 8 minutes.

OR

Press ALARM ON / OFF to turn the alarm off and activate it again after 24 hours.

PROJECTION

The ultra-bright LED enables daylight projection of time and temperature information.

To activate projection:

Slide PROJECTION to AUTO or CLOCK.

Slide to AUTO to toggle between current time and indoor / outdoor temperature.

Slide to CLOCK to project current time only.

To adjust the projection image:

Press 180° ROTATION to rotate the image by 180°.

Focus the projector image by turning the FOCUS wheel.

NOTE The installed CDS light sensor inside the unit will activate automatic projection / display dimming.

NOTE If projection is illuminated, do not look directly into the projector. Oregon Scientifi c will not be held responsible for any results or consequences arising from the misuse of this product.

TEMPERATURE

To toggle temperature unit:

Press °C / °F.

NOTE Please keep the temperature sensor (adjacent to the adaptor socket) away from the main unit or electrical devices as heat from these devices will affect accurate indoor temperature readings.

RESET

Press RESET to return to the default settings.

PRECAUTIONS

Do not subject the unit to excessive force, shock, dust, temperature or humidity.

Do not dispose old batteries as unsorted municipal

 

waste.Collection of such waste separately for special

 

treatment is necessary.

Please note that some units are equipped with a

 

battery safety strip. Remove the strip from the battery

 

compartment before fi rst use.

NOTE The technical specifi cations for this product and the contents of the user manual are subject to change without notice.

SPECIFICATIONS

TYPE

DESCRIPTION

MAIN UNIT

 

L x W x H

85 x 90 x 90 mm

(3.35 x 3.54 x 3.54 in)

 

Weight

510 g (17.99 oz)

without battery

 

 

 

Indoor temperature

0°C to 50°C

range

(32°F to 122°F)

 

 

Outdoor

-30°C to 60°C

temperature range

(-22°F to 140°F)

Resolution

0.1°C (0.2°F)

Signal frequency

433 MHz

Main power supply

DC 5.0V power adapter

Back-up power

1 x CR2032 3 V battery

supply

 

 

 

REMOTE UNIT (THN132N)

L x W x H

92 x 60 x 20 mm

(3.6 x 2.4 x 0.8 in)

 

 

 

Weight

62 g (2.22 oz)

Transmission range

30 m (98 ft) unobstructed

Temperature range

-30°C to 60°C

(-22°F to 140°F)

 

Power

1 x UM-4 (AA) 1.5 V

batteries

 

 

 

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientifi c.com) to learn more about Oregon Scientifi c products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientifi c.com/service/ support

OR

Call 1-800-853-8883.

For international inquiries, please visit: www2. oregonscientifi c.com/about/international

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

WARNING Changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and

Product Name:

Atomic Daylight Projection Clock

 

with Outdoor Temperature

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,Phase

 

1,41 Man Yue St.,Hung Hom,

 

Kowloon, Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

5

6

7

8

9

10

1.Capteurs de mouvements infrarouges (face supérieure) : Snooze (Rappel d’alarme) ; changement du mode d’affi chage

2.ALARM ON / OFF (face supérieure): Active / désactive l’alarme

3.Fuseaux horaires

4.Indicateur de réception du signal de l’horloge

5.Affi chage de l’horloge, de l’alarme et de la température

6.°C / °F Affi chage de l’unité de mesure de température

7.Icône de l’alarme

8.Icône de température extérieure

9.Indicateur de faiblesse des piles

10.Icône de température intérieure

11.Projecteur : Permet de projeter l’état de l’alarme et la température intérieure / extérieure

FACE ARRIÈRE / INFÉRIEURE

1.FOCUS : Mise au point de l’image projetée

2.Prise de l’adaptateur

3.Compartiment des piles

4.EU / UK : Permet de sélectionner le signal de réception de l’horloge

5.PROJECTION OFF / CLOCK / OFF : Permet de sélectionner le mode de projection

6.180° ROTATION : Permet de faire tourner l’image à 180 degrés

7.SET ALARM : Permet de régler l’alarme

8.SET CLOCK : Permet d’entrer dans le mode réglage de l’horloge

9.°C / °F : Permet de sélectionner l’unité de mesure de la température

10./ : Augmente / diminue les réglages ; active/ désactive le signal de réception de l’horloge

11.RESET (REINITIALISER) : Réinitialise l’appareil aux réglages par défaut

POUR COMMENCER

ALIMENTATION ÉLECTRIQUE

Veuillez utiliser les piles comme alimentation de secours uniquement. Si vous désirez utiliser continuellement le projecteur et le rétro éclairage, veuillez brancher l’adaptateur secteur. Assurez-vous que la prise soit facilement accessible.

Insérer les piles :

1.Ouvrez le compartiment des piles et insérez les piles en respectant les polarités.

2.Appuyez sur RESET (REINITIALISER) après chaque changement de piles.

Manual background indique que la pile de l’appareil principal est faible.

SONDE SANS FIL

Installation du capteur :

1.Ouvrez le compartiment des piles.

2.Sélectionnez un canal puis appuyez sur RESET.

3.Fermez le couvercle du compartiment des piles.

4.Installez le capteur à 30 m maximum (98 pieds) de l’appareil principal à l’aide du support de table ou de la fi xation murale.

ASTUCE La gamme de transmission peut varier en fonction de plusieurs facteurs. Vous pouvez essayer plusieurs emplacements, afi n d’obtenir les meilleurs résultats possibles.

TRANSMISSION DES DONNÉES DU CAPTEUR

L’appareil principal recherchera immédiatement le capteur extérieur. L’icône de réception du capteur situé sur la zone du capteur à distance vous indique le statut de la transmission :

ICONE

DESCRIPTION

 

Appareil principal à la

 

recherche du capteur.

 

Un canal a été trouvé.

 

 

 

Le capteur est

 

introuvable.

REMARQUE Si le capteur n’est pas localisé, vérifi ez les piles, les obstructions possibles et l’emplacement du capteur à distance.

Pour obtenir de meilleurs résultats :

Ne placez pas le capteur directement face aux rayons du soleil ou en contact direct avec la pluie.

Installez le capteur face à l’appareil principal en réduisant les obstructions possibles.

N’installez pas le capteur à proximité d’objets métalliques ou électroniques.

Installez le capteur à proximité de l’appareil principal pendant les périodes froides de l’hiver.

HORLOGE

RÉCEPTION DE L’HORLOGE

Ce produit est conçu pour synchroniser automatiquement l’horloge avec le signal radio.

DP200 :

Positionnez l’encoche EU / UK pour sélectionner le signal à recevoir.

EU : Signal DCF-77 : dans un rayon de 1500 Km (932 miles) depuis Frankfort, Allemagne.

UK : Signal MSF-60 : dans un rayon de 1500 Km (932 miles) depuis Anthorn, Angleterre.

DP200A :

1.Appuyez et maintenez la touche SET CLOCK.

2.Appuyez sur Manual background ou Manual background pour modifi er les réglages.

3.Appuyez sur SET CLOCK pour confi rmer.

4.Les réglages s’effectuent dans l’ordre suivant : décalage horaire, format 12 ou 24 heures, heure et minute.

DP200 : La fonction de fuseau horaire règle l’horloge à +/- 23 heures de l’heure du signal reçu.

AFFICHAGE LCD

Passez votre main devant les capteurs de mouvement infra rouge pour alterner entre les modes suivants :

Horloge

Alarme

Température extérieure

Température intérieure

L’ALARME

Pour régler l’alarme :

1.Appuyez et maintenez la touche SET ALARM.

2.Appuyez sur Manual background / Manual background pour régler l’heure / les minutes.

3.Appuyez sur SET ALARM pour confi rmer.

indique que l’alarme est activée.

Pour activer/désactiver l’alarme :

1.Appuyez sur SET ALARM pour affi cher l’heure de l’alarme.

2.Appuyez sur ALARM ON / OFF pour activer ou désactiver l’alarme.

Pour couper le son de l’alarme :

Passez votre main au dessus des capteurs de mouvement infrarouge pour couper le son pendant 8 minutes.

OU

Appuyez sur ALARM ON / OFF pour éteindre l’alarme et pour qu’elle se déclenche 24 heures plus tard.

PROJECTION

La forte clarté de la diode électroluminescente permet une projection de l’heure et de la température en journée.

Pour activer la projection :

Positionnez l’encoche PROJECTION sur AUTO ou sur CLOCK.

Placez l'encoche sur AUTO pour alterner entre l’heure actuelle et la température intérieure / extérieure.

Positionnez l'encoche sur CLOCK pour ne projeter que l’heure actuelle.

Pour ajuster l’image projetée :

Appuyez sur 180° ROTATION pour faire tourner l’image à 180°.

Tournez la molette FOCUS pour mettre au point l‘image projetée.

REMARQUE Le capteur de lumière CDS situé à l’intérieur de l’appareil activera l’intensité automatique de l’écran LCD et de la projection.

REMARQUE Si la projection est activée, ne regardez pas directement dans le projecteur. Oregon Scientifi c ne sera en aucun cas responsable des conséquences ou résultats découlant de la mauvaise utilisation de ce produit.

4/9/08 2:47:26 PM

Page 1
Image 1
Oregon Scientific user manual Atomic Daylight Projection Clock with Outdoor Temperature, Model DP200 / DP200A