Oregon Scientific WMR88A Temperature / Humidity Sensor, Mounting / Placing Of Sensors Wind Sensor

Models: WMR88A

1 10
Download 10 pages 31.59 Kb
Page 5
Image 5
TEMPERATURE / HUMIDITY SENSOR

WIND SENSOR

Press SELECT until the selected area icon is in the top right display area.

Wind speed: Gently rotate the wind vane and confirm

a numerical reading on the base station, e.g.,MOUNTING / PLACING OF SENSORS WIND SENSOR.

Wind direction indicator. Move the direction of the

wind indication and verify the icon moves in the same direction Manual background.

TEMPERATURE / HUMIDITY SENSOR

a.Align the back of the sensor connector to an existing pole. Secure in place by inserting the ends of the U-bolt into the holes on the sensor connector and securing it with washers and bolts.

OR

b.Insert 4 type A screws into the holes of the sensor connector. Screw firmly into place, i.e., fence.

Slide wind vane onto the smaller end of the sensor connector.

IMPORTANT Ensure that the wind sensor is pointing North to enable it to record accurate readings.

TEMPERATURE / HUMIDITY SENSOR

EN

1.

Press SELECT until the selected area icon is in

 

the bottom left display area.

 

2.

Press UP / DOWN to select channel 1

and verify

 

a numerical reading.

 

RAIN GAUGE

1.

Press SELECT until the selected area icon is in

 

the middle right display area.

2.

Press MODE until

is displayed.

3.Tilt the tipping funnel on the rain gauge several times and verify a numerical reading on the base station.

TIP If no reading is displayed for a sensor, press the SEARCH button on the base station to initiate a wireless sensor search.

MOUNTING / PLACING OF SENSORS WIND SENSOR

NOTE The sensor should be positioned in an open area away from trees or other obstructions.

ab

Secure the sensor connector in the desired location:

5

1.5 m (5 ft)

TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading.

Secure the sensor in the desired location using the wall mount bracket or table stand.

RAIN GAUGE

The base station and rain gauge should be positioned within an effective range: about 100 meters (328 feet) in an open area.

The rain gauge should be mounted horizontally about 1 meter (3 feet) from the ground in an open area away from trees or other obstructions to allow rain to fall naturally for an accurate reading.

Page 5
Image 5
Oregon Scientific WMR88A user manual Temperature / Humidity Sensor, Mounting / Placing Of Sensors Wind Sensor, Rain Gauge