
  | 
  | 
  | |
Figure 6. Lower the assembled mirror cell onto the tube | 
  | ||
so one side of the end ring is seated on the tube edge. The | 
  | ||
Figure 7. Locate the area of tube that is bulging out and | |||
threaded attachment holes in the end ring should also be  | |||
lined up with the through holes in the end of the tube  | preventing the mirror cell from fully seating.  | ||
of engagement on the shafts. The mirror cell is now ready to  | Replace the six   | ||
be installed into the tube.  | |||
end ring to the tube.  | |||
  | 
  | ||
Assembling the SkyQuest XT12 mirror cell to the tube can be  | Assembly of the Dobsonian base | |||
a bit tricky. This is because the large diameter and thin steel  | ||||
of the tube will cause the tube to become somewhat out of  | Refer to Figure 9 during base assembly. The base need  | |||
round once the rear end ring is removed.  | only be assembled once, unless you disassemble it for long-  | |||
To assemble the mirror cell to the tube, stand the tube up  | term storage. The assembly process takes about 30 minutes  | |||
and requires a Phillips screwdriver, an adjustable crescent  | ||||
vertically so that the raw edge of the tube is facing upwards.  | ||||
wrench, and the provided hex keys. When tightening screws,  | ||||
Line up the threaded holes in the edge of the mirror cell end  | ||||
  | 
  | 
  | ||
ring with the holes in the end of the tube. Then, lower the  | 
  | 
  | 
  | |
mirror cell onto the tube so that one side of the end ring is  | 
  | 
  | 
  | |
fully seated onto the tube (Figure 6). Now, look along the  | 
  | 
  | 
  | |
perimeter of the tube, and you will notice a bulge in the tube  | 
  | C  | 
  | |
that prevents the mirror cell from fully seating on the tube  | 
  | 
  | 
  | |
(Figure 7). Position your body so that your chest is pressing | 
  | 
  | C  | |
against this bulge, and hug the telescope with your left hand | 
  | 
  | ||
  | 
  | B  | ||
so that the tube becomes round. With your right hand, gently | 
  | 
  | ||
  | 
  | 
  | ||
tap down the side of the mirror cell that needs to be seated, | 
  | 
  | 
  | |
and the entire mirror cell should seat onto the tube (Figure 8). | 
  | 
  | L  | |
  | 
  | 
  | I  | |
  | J  | 
  | H  | |
  | 
  | 
  | E  | |
  | 
  | D  | 
  | |
  | 
  | A  | K  | |
  | 
  | 
  | ||
  | 
  | 
  | F  | |
  | 
  | 
  | G  | |
Figure 8. Hug the tube so that your chest pushes against the | 
  | 
  | 
  | |
bulge, and a gentle tap should fully seat the mirror cell onto the | 
  | 
  | 
  | |
tube. | Figure 9. Exploded view of the Dobsonian base. | |||
  | 
  | 
  | 5  | |