Specifications

Single Inverter Split

Cooling (

): Outdoor Unit EER: Cooling Efficiency

Heating

COP: Heating Efficiency

Model No.

Cooling Capacity

 

 

External

Running

Power

EER

 

 

Sound Pressure

Sound Power

 

Dimensions

Maximum

Power

 

Heating

Capacity

Air Flow

Dehumid

Static

Current

Input

COP

Star

Level*1

dB (A)

Level dB (A)

Net Weight

Height x Width x Depth

Pipe

2

Supply

 

 

 

 

 

Pressure

 

 

 

Rating

 

 

 

 

 

 

Length*

 

 

(240V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

Btu/h

L/s

L/h

Pa(mmAq)

A

kW

W/W

 

 

Inside (Hi/Lo)

Outside (Hi/Lo)

Outside

kg

mm

m

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.60

8,870

177

 

 

2.7

0.57

4.56

6.0

 

 

46 / —

59

 

305 x 870 x 229

 

 

 

CS-XE9EKE

(0.60~3.00)

(2,050~10,200)

1.6

(0.12~0.70)

39 / 26

13

15

 

Indoor

(CU-XE9EKE)

3.60

12,300

195

3.7

0.81

4.44

6.0

40 / 27

47 / —

60

(37)

(540 x 780 x 289)

 

 

 

 

 

10

 

(0.60~6.10)

(2,050~20,800)

 

 

 

 

(0.115~1.64)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-XE12EKE

3.50

11,900

 

 

 

 

0.88

 

 

 

 

 

 

 

 

 

 

 

 

(0.60~4.00)

(2,050~13,600)

198

2.0

4.0

(0.12~1.10)

3.98

6.0

42 / 29

48 / —

61

13

305 x 870 x 229

15

 

Indoor

(CU-XE12EKE)

4.80

16,400

212

5.4

1.22

3.93

6.0

42 / 33

50 / —

63

(37)

(540 x 780 x 289)

 

 

 

 

 

10

 

(0.60~6.70)

(2,050~22,800)

 

 

 

 

(0.115~1.84)

 

 

 

 

 

 

 

 

 

 

 

 

 

2.60

8,870

160

 

 

2.8

0.60

4.33

6.0

 

 

46 / —

59

 

280 x 799 x 183

 

 

 

CS-E9FKR

(0.80~3.00)

(2,730~10,200)

1.6

(0.175~0.78)

39 / 26

9

15

 

Outdoor

(CU-E9FKR)

3.60

12,300

175

3.8

0.845

4.26

6.0

40 / 27

47 / —

60

(37)

(540 x 780 x 289)

 

 

 

 

 

10

 

(0.80~5.00)

(2,730~17,100)

 

 

 

 

(0.165~1.36)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.50

11,900

 

 

 

 

0.965

 

 

 

 

 

 

 

 

 

 

 

 

CS-E12FKR

(0.80~4.00)

(2,730~13,600)

178

2.0

4.3

(0.185~1.20)

3.63

6.0

42 / 29

48 / —

61

9

280 x 799 x 183

15

 

Outdoor

(CU-E12FKR)

4.90

16,700

187

5.6

1.26

3.89

5.5

42 / 33

50 / —

63

(37)

(540 x 780 x 289)

 

 

 

 

 

10

 

(0.80~6.70)

(2,730~22,800)

 

 

 

 

(0.175~1.89)

 

 

 

 

 

 

 

 

 

 

 

 

 

4.40

15,000

 

 

 

 

1.37

 

 

 

 

 

 

 

 

 

 

 

 

CS-E15FKR

(0.90~5.00)

(3,070~17,100)

183

2.4

6.2

(0.215~1.60)

3.21

4.5

43 / 32

46 / —

59

9

280 x 799 x 183

15

 

Outdoor

(CU-E15FKR)

5.50

18,800

197

7.0

1.57

3.50

4.5

43 / 35

46 / —

59

(48)

(750 x 875 x 345)

 

 

 

 

 

10

 

(0.90~7.10)

(3,070~24,200)

 

 

 

 

(0.245~2.25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.30

18,100

 

 

 

 

1.65

 

 

 

 

 

 

 

 

 

 

 

 

CS-E18FKR

(0.90~6.00)

(3,070~20,500)

253

2.9

7.3

(0.215~2.05)

3.21

4.5

44 / 37

47 / —

60

11

275 x 998 x 230

20

 

Outdoor

(CU-E18FKR)

6.60

22,500

278

7.9

1.79

3.69

5.0

44 / 37

47 / —

60

(49)

(750 x 875 x 345)

 

 

 

 

 

15

 

(0.90~8.00)

(3,070~27,300)

 

 

 

 

(0.245~2.65)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.30

21,500

 

 

 

 

2.06

 

 

 

 

 

 

 

 

 

 

 

 

CS-E21FKR

(0.90~7.10)

(3,070~24,200)

270

3.5

9.0

(0.215~2.40)

3.06

4.0

45 / 37

48 / —

61

11

275 x 998 x 230

20

 

Outdoor

(CU-E21FKR)

7.20

24,600

288

8.8

2.00

3.60

4.5

45 / 37

49 / —

62

(51)

(750 x 875 x 345)

 

 

 

 

 

20

 

(0.90~8.50)

(3,070~29,000)

 

 

 

 

(0.245~2.70)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-E24FKR

7.20

24,600

 

 

 

 

2.30

 

 

 

 

 

 

 

 

 

 

 

 

(0.90~8.10)

(3,070~27,600)

282

4.2

10.3

(0.35~2.70)

3.13

4.0

47 / 38

52 / —

66

12

275 x 998 x 230

30

 

Outdoor

(CU-E24FKR)

8.60

29,300

305

11.1

2.51

3.43

4.0

47 / 38

52 / —

66

(72)

(795 x 900 x 320)

 

 

 

 

 

20

 

(0.90~9.90)

(3,070~33,800)

 

 

 

 

(0.36~3.20)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-E28FKR

8.10

27,600

 

 

 

 

2.72

 

 

 

 

 

 

 

 

 

 

 

 

(0.90~8.60)

(3,070~29,300)

295

4.8

12.0

(0.35~2.95)

2.98

3.5

49 / 38

53 / —

67

12

275 x 998 x 230

30

 

Outdoor

(CU-E28FKR)

9.60

32,700

312

14.4

3.25

2.95

3.0

48 / 38

53 / —

67

(72)

(795 x 900 x 320)

 

 

 

 

 

20

 

(0.90~11.00)

(3,070~37,500)

 

 

 

 

(0.36~3.79)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Sound Pressure Level is measured according to JIS C 9612. *2 Additional Gas might be required for some models.

Single Split

Cooling (

): Outdoor Unit EER: Cooling Efficiency

Heating

COP: Heating Efficiency

Model No.

Cooling Capacity

 

 

Running

Power

EER

 

Sound Pressure

Sound Power

 

Dimensions

Maximum

Power

Air Flow

Dehumid

 

Net Weight

Pipe

 

 

 

Heating Capacity

Current

Input

COP

Star

Level*1 dB (A)

Level dB (A)

Height x Width x Depth

2

Supply

 

 

 

 

 

 

 

 

 

Rating

 

 

 

 

 

 

Length*

 

 

 

(240V)

kW

Btu/h

L/s

L/h

A

kW

W/W

 

Inside (Hi/Lo)

Outside (Hi/Lo)

Outside

kg

mm

m

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-W7DKR

 

2.30

7,840

132

1.5

3.2

0.72

3.19

5.0

34/26

47/—

62

9

280 x 799 x 183

10

 

Indoor

(CU-W7DKR)

 

2.45

8,350

152

3.0

0.685

3.58

6.0

36/26

49/—

64

(26)

(510 x 650 x 230)

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-W9DKR

2.75

9,380

143

1.6

3.8

0.875

3.14

4.5

36/26

49/—

64

9

280 x 799 x 183

10

 

Indoor

(CU-W9DKR)

3.05

10,400

162

3.8

0.865

3.53

5.5

39/26

50/—

65

(29)

(510 x 650 x 230)

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-W12EKR

 

3.60

12,300

178

2.1

5.0

1.1

3.27

4.5

41/29

50/—

65

8

280 x 799 x 183

15

 

Indoor

(CU-W12EKR)

 

3.90

13,300

182

4.9

1.09

3.58

4.5

42/29

50/—

66

(35)

(540 x 780 x 289)

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-W18DKR

5.30

18,100

255

2.9

7.8

1.81

2.93

4.0

43/38

50/—

63

11.0

275 x 998 x 230

25

 

Indoor

(CU-W18DKR)

5.75

19,600

267

7.8

1.80

3.19

3.5

42/38

51/—

64

(56.0)

(750 x 875 x 345)

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS-W24EKR

 

7.03

24,000

290

4.0

11.1

2.37

2.97

3.5

47/41

53/—

66

11.0

275 x 998 x 230

25

 

Indoor

(CU-W24EKR)

 

7.80

26,600

303

11.7

2.46

3.17

3.0

46/41

54/—

67

(63.0)

(750 x 875 x 345)

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Sound Pressure Level is measured according to JIS C 9612. *2 Additional Gas might be required for some models.

Rating Conditions

 

Cooling

Heating

Inside air temperature

27°C DB/19°C WB

20°C DB

 

 

 

Outside air temperature

35°C DB

7°C DB/6°C WB

 

 

 

Power plugs are not supplied with the unit.

Electrical work must be installed by a licensed electricians. Be sure to use the correct rating of the power plug and mains circuit for the model to be installed.

Please read the Installation Instructions carefully before installing the unit, and read the Operating Instructions before using.

19

Page 19
Image 19
Panasonic 2006/2007 manual Specifications, Rating Conditions