A Clean Filter Greatly Boosts Performance, Giving

Comparison of Mould Growth

A dirty filter is a natural breeding ground for mould and house mites. Their growth can be greatly reduced by keeping the filter clean.

Without filter cleaning With auto filter cleaning

Observation of mould on filters

(used for 3 months) after cultivation on agar media for 3 days.

Testing organization: Japan Food Research Laboratories Test No.: 204090946-001

Airflow Comparison

 

100

 

 

 

(%)

 

With auto filter

 

 

 

 

 

 

cleaning

 

 

 

 

 

flow

75

 

No cleaning

 

 

 

 

Air

50

 

 

 

 

 

 

 

 

0

 

 

 

 

1

Time (year)

3

 

 

 

 

 

 

No filter maintenance will cause air volume to drop

25% in 1 year

50% in 3 years

Class A energy saving achieved by inverter technology

Panasonic's high-efficiency technologies clear stringent energy-saving standards, and the AC Robot maintains this high level of performance.

Comparison of

Comparison of EER

Comparison of COP

Heating Capacity

 

 

 

 

at maximum operation

at cooling operation

at heating operation

 

6.10kW

 

 

Energy

 

 

 

Energy

4.56

Efficiency

4.44

 

 

Class

 

 

Efficiency

 

 

A>3.60

 

 

Class

 

 

A>3.20

 

3.61

 

 

 

3.22

 

 

3.05kW

 

 

 

 

 

 

 

 

Inverter

 

Inverter

 

Inverter

Non-Inverter

Super Deluxe

Non-Inverter

Super Deluxe

Non-Inverter

Super Deluxe

(CS-W9DKR)

(CS-XE9EKE)

(CS-W9DKR)

(CS-XE9EKE)

(CS-W9DKR)

(CS-XE9EKE)

Temperature Distribution Comparison

With the AC Robot, heating performance is maintained even after long use. On the other hand, the power is reduced without filter cleaning.

 

 

 

New (Just installed)

 

With auto filter cleaning

 

Without filter cleaning

 

 

 

 

 

(After 3 years)

 

 

(After 3 years)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

view

 

 

 

 

22 ˜ 24˚C

 

 

 

22 ˜ 24˚C

 

 

 

Below 24˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

 

 

 

26 ˜

24 ˜ 26˚C

 

 

 

26 ˜

 

 

 

 

 

 

 

 

 

 

28˚C

 

 

 

28˚C 24 ˜ 26˚C

 

 

 

Above

24 ˜ 26˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26˚C

 

 

 

 

 

 

 

 

The powerful airflow reaches

The airflow drops and the

 

 

 

 

 

 

 

throughout the room. Even

air stream doesn't reach

 

 

 

 

 

 

 

the area around your feet

the corners of the room.

 

 

 

 

 

 

 

stays nice and warm.

 

 

 

 

 

 

 

 

 

23

˜

 

 

 

 

23 ˜

 

 

 

 

20 ˜

 

 

 

 

26˚C

 

 

 

 

26˚C

 

 

 

 

22˚C

 

area

 

 

 

Above

 

 

 

 

Above

 

 

 

Above

 

 

 

 

 

 

 

 

 

Floor

 

 

 

26˚C

 

 

 

 

26˚C

 

 

 

26˚C

 

 

 

 

 

20 ˜

 

 

 

20 ˜

 

 

 

22

˜ 26˚C

 

 

 

 

 

 

 

 

 

 

 

 

Below

 

 

 

 

 

 

 

22 ˜ 26 ˚C 22˚C

 

 

 

22 ˜ 26 ˚C 22˚C

 

 

 

20˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Test conditions>

•Starting temperature and humidity: 7˚C, 6˚C •Set temperature: 23˚C •Fan speed/airflow direction:

set to auto mode •After air conditioning stabilizes •Area of simulated-house testing facility: 16.5m2

How It Works

A detailed cleaning programme built into the AC Robot ensures that the entire filter surface stays clean with a highly efficient cleaning process.

The filter surface is divided into 12 blocks, and the vacuum nozzle cleans each block with a round-trip cleaning operation.

The number of blocks (amount of surface area) to be cleaned is determined

according to the air conditioner's cumulative operating time.

Cleaning of the entire surface is completed after 36 operating hours are accumulated.

12

. . .

. . . 3 2 1

In the High fan speed in the normal setting mode

Cumulative operation hours (hour)

No. of cleaning operations

Less than 2

No cleaning

2

- <6

2 round-trip

6

- <9

3 round-trip

9

- <12

4 round-trip

<12

5 round-trip

 

 

 

Auto Filter Cleaning Operation Patterns

Two operations are available. In addition to the normal setting, the timer setting can also be used.

Air Conditioner Operating

Auto Filter Cleaning

Stop

In the normal setting mode (non-timer)

Cleaning automatically starts after each operation. The number of round-trip is determined based on the cumulative operating time.

In the timer setting mode

Cleaning starts at the set time everyday.

*If the air conditioner has not been used for more than 30 minutes since it was cleaned, the cleaning operation will not be done at the preset time.

 

 

 

 

 

 

2 round-trip operations

 

 

 

 

 

2 round-trip operations or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

Less than

 

 

 

2 to 3 h

 

 

 

 

 

4 hours or more

 

 

 

2 h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No cleaning if less than 2 h

 

 

Cleaning starts

 

 

 

 

 

 

Cleaning starts

 

 

Timer set time

2 round-trip operations

Timer set time

2 round-trip operations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

Operation time:

 

 

 

 

1 h

 

 

 

1 h

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 h

 

 

 

 

 

 

 

min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cleaning starts at set time

 

 

Air conditioner stops operation temporarily

 

After cleaning, air conditioner

 

 

 

 

 

 

 

 

at the set time, and cleaning starts

automatically resumes operation.

 

08

Page 8
Image 8
Panasonic 2006/2007 Comparison of Mould Growth, Airflow Comparison, Class a energy saving achieved by inverter technology