08
A detailed cleaning programme built into the AC Robot ensures that the entire filter surface stays clean with a highly efficient cleaning process.Panasonic's high-efficiency technologies clear stringent energy-saving standards, and the AC Robot maintains this high level of performance.
How It Works
Class A energy saving achieved
by inverter technology
Auto Filter Cleaning Operation Patterns
Comparison of Mould Growth
A dirty filter is a natural breeding ground for mould and house mites. Their growth can be greatly reduced by keeping the filter clean.
In the normal setting mode (non-timer)
Cleaning automatically starts after each operation. The number of round-trip is determined based on the cumulative operating time.
In the timer setting mode
Cleaning starts at the set time everyday.
* If the air conditioner has not been used for more than 30 minutes since it
was cleaned, the cleaning operation will not be done at the preset time.
With the AC Robot, heating performance is maintained even after long use. On the other hand, the power is reduced without filter cleaning.
Observation of mould on filters
(used for 3 months) after cultivation
on agar media for 3 days.
Testing organization: Japan Food
Research Laboratories Test No.:
204090946-001
Temperature Distribution Comparison
Airflow Comparison
Without filter cleaningWith auto filter cleaning1005075031Air flow (%)Time (year)No cleaningWith auto filtercleaning
50% in 3 years
25% in 1 year
Without filter cleaning
(After 3 years)
With auto filter cleaning
(After 3 years)
New (Just installed)
The powerful airflow reaches
throughout the room. Even
the area around your feet
stays nice and warm.
The airflow drops and the
air stream doesn't reach
the corners of the room.
Side viewFloor area

A Clean Filter Greatly Boosts Performance, Giving

No filter maintenance will cause air volume to dropLess than2 h 2 to 3 h 4 hours or more Time1 h 30minOperation time:4 h2 round-trip operations2 round-trip operations2 round-trip operationsCleaning starts at set timeCleaning startsNo cleaning if less than 2 h Cleaning startsAir conditioner stops operation temporarily at the set time, and cleaning starts2 round-trip operations or moreTimeTwo operations are available. In addition to the normal setting, the timer setting can also be used.
1
12
2
3
.
.
.
...Cumulative operation hours (hour)Less than 22 - <6 6 - <99 - <12<12No. of cleaning operationsNo cleaning2 round-trip3 round-trip4 round-trip5 round-trip
Air Conditioner Operating
Auto Filter Cleaning
Stop
Timer set timeTimer set time
In the High fan speed in the normal setting mode
1 hThe filter surface is divided into 12 blocks, and the vacuum nozzle cleans each block with a round-trip cleaning operation. The number of blocks (amount of surface area) to be cleaned is determined according to the air conditioner's cumulative operating time.Cleaning of the entire surface is completed after 36 operating hours are accumulated. Comparison ofHeating Capacity Comparison of COPat heating operationComparison of EERat cooling operationat maximum operation
Non-Inverter
(CS-W9DKR)
Non-Inverter
(CS-W9DKR)
Non-Inverter
(CS-W9DKR)
Inverter
Super Deluxe
(CS-XE9EKE)
6.10kW
3.05
kW
3.613.22
Inverter
Super Deluxe
(CS-XE9EKE)

4.44

Inverter
Super Deluxe
(CS-XE9EKE)

4.56

Energy
Efficiency
Class
A>3.60
Energy
Efficiency
Class
A>3.20
After cleaning, air conditioner automatically resumes operation.
<Test conditions>
•Starting temperature and humidity: 7˚C, 6˚C •Set temperature: 23˚C •Fan speed/airflow direction:
set to auto mode •After air conditioning stabilizes •Area of simulated-house testing facility: 16.5m2
22 ˜ 24˚C
24 ˜ 26˚C
26 ˜
28˚C
Above
26˚C
22 ˜ 26 ˚C
23 ˜
26˚C
20 ˜
22˚C
22 ˜ 24˚C
24 ˜ 26˚C
26 ˜
28˚C
Above
26˚C
22 ˜ 26 ˚C
23 ˜
26˚C
20 ˜
22˚C
Above
26˚C 24 ˜ 26˚C
Below 24˚C
Below
20˚C
20 ˜
22˚C
22 ˜ 26˚C
Above
26˚C