Problem

 

Cause and Remedy

 

The unit will not operate at all.

 

• The power cord has been disconnected. (See page 16)

• Upper body (neck to lower back) massage

 

• The power switch on the unit has not been turned on.

• Lower body (calves) massage

 

• A Pre-Program button or Manual Operation button hasn’t

 

 

 

 

been pressed after pressing

.

 

 

 

 

Sometimes the power won’t turn on when

is pressed

Approximately 5 seconds are required for program termination

after a massage finishes. Wait at least 5 seconds once all

again when a massage has finished.

 

 

 

movement has stopped before pressing

.

 

 

 

 

 

The unit has been damaged.

 

Stop using the unit immediately.

 

 

The power cord or power plug is abnormally hot.

Stop using the unit immediately.

 

 

Warning

Do not attempt to repair, disassemble or modify the unit.

Failure to observe this precaution may result in fire or injury due to malfunctioning.

Caution

Unplug the power plug immediately and contact a customer service center to arrange for repairs if the unit ceases to function or is otherwise not working properly.

Failure to observe this precaution may result in electric shock or fire.

SPECIFICATIONS

Power supply

Power consumption

 

Massage area (Up-Down)

Upper

Massage area (Left-Right)

Massage area (Forward-back)

body

Massage speed

massage

Lateral/Vertical Travel

 

 

Massage width

Air massage

Air Pressure (Calf)

 

Reclining angle

Automatic Shut-off

Dimensions

When not reclined

(H × W × D)

 

(H × W × D)

 

When reclined

Weight of Unit

Dimension of box (H × W × D)

Weight in box

Maximum user weight

Minimum distance from wall

AC 120 V 60 Hz

175 W

Approx. 30 in. (76 cm) (The massage heads move a total of approx. 26 in. (65 cm))

Distance between massage heads during operation (massage width adjustable) Neck, Shoulder, Back, Lower back: Approx. 3 – 8 in. (7 – 21 cm)

Projected amount of massage head (Intensity adjustable)

Approx. 4 in. (10 cm)

Tap: Approx. 250 – 450 cycles/minute (single side)

Full roll: Approx. 26 – 92 seconds (both ways)

Other than the above: approx. 6 – 50 cycles/minute

Lateral travel: Approx. 1.5 in. (3.8 cm) left-right auto return

Vertical travel (Long): Approx. 30 in. (76 cm) up-down auto return

Vertical travel (Short): Approx. 4 in. (10 cm) up-down auto return

Full roll, Vertical Movement: Approx. 3 – 7 in. (7 – 18 cm)

Other than the above: Same as massage area (left-right)

5:Approx. 32 kPa

4:Approx. 29 kPa

3:Approx. 21 kPa

2:Approx. 11 kPa

1:Approx. 4 kPa

* It may vary with the area slightly.

Backrest: Approx 120˚ – 170˚

Legrest: Approx 0˚ – 85˚

Automatically turns off after approx. 15 minutes (approx. 5 minutes for the quick massage)

Approx. 47.2 × 33.1 × 50 in. (120 × 84 × 127 cm)

Approx. 28.3 × 33.1 × 76.8 in. (72 × 84 × 195 cm)

Approx. 159 lbs. (72 kg)

Approx. 28.3 × 30.7 × 65.4 in. (72 × 78 × 166 cm)

Approx. 194 lbs. (88 kg)

Approx. 264 lbs (120 kg)

15.7 in. (40 cm)