– 65 –
USER menu <EDIT> (continued)
Item Setting
No.
Superimposed
No.
Superimposed
Description
display display
318 VAR REV 0000 –4.1
MAX 0001 –1.85
0002 –1
0003 –0.43
0004 –0.3
0005 –0.2
0006 –0.1
0007 –0.03
319 JOG STEP 0000 FINE
0001 COARSE
320 JOG FWD 0000 +4.1
MAX 0001 +1.85
0002 +1
321 JOG REV 0000 –4.1
MAX 0001 –1.85
0002 –1
0003 –0.43
The underline on the setting item denotes the initial setting.
This sets the maximum VAR REV speed.
0: –4.1× (–3.1×) speed
1: –1.85× (–1.85×) speed
2: –1× (–1×) speed
3: –0.43× (–0.5×) speed
4: –0.3× (–0.3×) speed
5: –0.2× (–0.2×) speed
6: –0.1× (–0.1×) speed
7: –0.03× (–0.03×) speed
<Notes>
The tape will be played at the speed given in parentheses in
the DV/DVCAM mode.
In the DV/DVCAM mode, the maximum speed is set to –0.5×
when the dial on the front panel is operated.
This selects the JOG speed during remote control operations.
0: The tape is played at the fine step speed.
1: The tape is played at a speed at which noise-less playback
is possible in the –0.43× to +1× (–0.5× to +1×) range.
<Notes>
The tape will be played at the speed given in parentheses in
the DV/DVCAM mode.
• At the 1 (COARSE) setting, the phase cannot be synchro-
nized from an editing controller which synchronizes the
phase using the JOG command.
This sets the maximum JOG FWD speed.
0: +4.1× (+3.1×) speed
1: +1.85× (+1.85×) speed
2: +1× (+1×) speed
<Notes>
The tape will be played at the speed given in parentheses in
the DV/DVCAM mode.
The maximum speed is set to +1× when the dial on the front
panel is operated.
At any speed setting other than 0 (+4.1), the phase cannot
be synchronized from an editing controller which synchro-
nizes the phase using the JOG command.
This sets the maximum JOG REV speed.
0: –4.1× (–3.1×) speed
1: –1.85× (–1.85×) speed
2: –1× (–1×) speed
3: –0.43× (–0.5×) speed
<Notes>
The tape will be played at the speed given in parentheses in
the DV/DVCAM mode.
When the dial on the front panel is operated, the maximum
speed is set to –1× in the DVCPRO mode and to –0.5× in
the DV/DVCAM mode.