Setup menu No. 505 (EXT TC SEL) can be set as follows.
LTC: The LTC signal input to the TIME CODE IN connector (XLR) on the rear jack panel is recorded as the time code.
<Note> The LTC signal must be synchronized with the video signal. VITC: The input video signal’s VITC is recorded as the time code.
– 62 –
4
Set the TC INT/EXT switch to EXT. (External time code selected)
3
Set the TC/CTL switch to TC.
2
Place the VTR in the stop mode.
1
2 Press the ADJ button to change the value.
Each time the button is pressed, the number changes. The setting range is given below.
When using the time code and user bit in real time 00:00:00:00 – 23:59:59:29
User bit
00 00 00 00 – FF FF FF FF
3 Repeat steps 1 and 2 to change the value.
4 When the setting of the start number is completed, press the START button. In the FREE RUN mode, the time code now starts running.
5 Proceed with the recording or editing.
2. Setting the external time code (TC switch EXT)
Set the TC SET button.
Use the TC SET button to set the start number of the time code or user bit. 1 Press the SHIFT button.
The leftmost digit flashes.
5
6

Recording internal/external time codes

1. Setting the internal time code

1 Place the VTR in the stop mode.

2 Set the TC/CTL switch to TC.

3 Set the TC INT/EXT switch to INT. (Internal time code selected)

4 Set the REC RUN/FREE RUN switch position.

REC RUN: The time code runs at the same time as the recording proceeds.

FREE RUN: The time code runs in the same way as the time regardless of the VTR’s operation.

Set the REGEN/PRESET switch position.

REGEN: Continuity is maintained with the recorded time code before editing. (Detailed settings are also possible using the menu settings. See the menu items below.)

Setup menu No. 503 (TCG REGEN) Setup menu No. 504 (REGEN MODE)

PRESET: Recording starts from the value set with the TC SET button.

<Note>

During auto editing, REGEN will be selected by the setup menu No. 504 setting even if the switch has been set to the PRESET position.