Setup Menus

TIME CODE

 

Item

 

Setting

 

 

 

 

 

Description of setting

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

VITC BLANK

 

 

For setting whether to output the VITC signal to the position set by menu

 

 

 

 

item No.501 (VITC POS-1) and No.502 (VITC POS-2).

 

 

0000

BLANK

0: The VITC signal is not output.

 

 

0001

THRU

1: The VITC signal is output.

 

 

 

 

<Note>

 

 

 

 

This setting is only effective for SD outputs (VIDEO output and SD SDI

 

 

 

 

output).

 

 

 

 

 

501

VITC POS-1

0000

10L

For setting the position where the VITC signal is to be inserted.

 

 

:

:

<Notes>

 

 

0006

16L

O The same line as that set for menu item No.502 (VITC POS-2) cannot

 

 

:

:

be set.

 

 

0010

20L

O This setting is only effective for SD outputs (VIDEO output and SD SDI

 

 

 

 

output).

 

 

 

 

 

502

VITC POS-2

0000

10L

For setting the position where the VITC signal is to be inserted.

 

 

:

:

<Notes>

 

 

0008

18L

O The same line as that set for menu item No.501 (VITC POS-1) cannot

 

 

:

:

be set.

 

 

0010

20L

O This setting is only effective for SD outputs (VIDEO output and SD SDI

 

 

 

 

output).

 

 

 

 

 

503

REGEN

 

 

For setting the synchronization method of the internal time code generator.

 

 

0000

REGEN

0: The time code reader is synchronized to the time code which is read

 

 

 

 

from the tape.

 

 

0001

PRE

1: The synchronization method can be preset by a front panel operation or

 

 

 

 

using the remote controller.

 

 

 

 

 

504

RUN MODE

 

 

For setting the operation mode in which the internal time code generator

 

 

 

 

advances the time code.

 

 

0000

REC

0: The generator advances only during recording.

 

 

0001

FREE

1: It advances while the power is on regardless of the operation mode.

 

 

 

 

 

505

TCG REGEN

 

 

For setting the signal to be regenerated when the TCG (time code

 

 

 

 

generator) is in the regeneration mode.

 

 

0000

TC&UB

0: Both the time code and user’s bit are regenerated.

 

 

0001

TC

1: Only the time code is regenerated.

 

 

0002

UB

2: Only the user’s bit is regenerated.

 

 

 

 

 

508

BINARY GP

 

 

For setting the conditions under which the user’s bit in the time code

 

 

 

 

generated by TCG is to be used.

 

 

0000

000

0: Not specified (character set is not specified).

 

 

0001

001

1: ISO characters (8-bit character set compliant with ISO646, ISO2022)

 

 

0002

010

2: Unassigned 1 (not defined)

 

 

0003

011

3: Unassigned 2 (not defined)

 

 

0004

100

4: Unassigned 3 (not defined)

 

 

0005

101

5: Page/line

 

 

0006

110

6: Unassigned 4 (not defined)

 

 

0007

111

7: Unassigned 5 (not defined)

 

 

 

 

 

509

PHASE CORR

 

 

For setting whether to control the phase compensation for the LTC output

 

 

 

 

during playback.

 

 

0000

OFF

0: The phase compensation is not controlled.

 

 

0001

ON

1: The phase compensation is controlled.

 

 

 

 

 

The underlining denotes the factory mode.