Setup Menus
INTERFACE
| Item |
| Setting |
|
|
|
|
|
|
| Description of setting |
No. | Superimposed | No. | Superimposed |
| |
|
| ||||
display | display |
|
| ||
|
|
|
| ||
|
|
|
|
| |
|
|
|
|
| |
202 | ID SEL |
|
| For setting the ID information to be returned to the controller. | |
|
| 0000 | OTHER | 0: 20 25H is returned. | |
|
| 0001 | DVCPRO | 1: The ID | (F0 33H) unique to the DVCPRO is returned. |
|
| 0002 | ORIG | 2: The ID | (A0 51H) unique to the unit is returned. |
|
|
|
|
|
|
The underlining denotes the factory mode.
TAPE PROTECT
| Item |
| Setting |
| |
|
|
|
| Description of setting | |
No. | Superimposed | No. | Superimposed | ||
| |||||
display | display |
| |||
|
|
| |||
|
|
|
|
| |
|
|
|
|
| |
400 | STILL TIMER | 0000 | 0.5S | For setting the time taken before the unit is set to the tape protection mode | |
|
| 0001 | 5S | when it has been left in the STOP or STILL mode. | |
|
| 0002 | 10S | (Unit: S = seconds, min: minutes) | |
|
| 0003 | 20S |
| |
|
| 0004 | 30S |
| |
|
| 0005 | 40S |
| |
|
| 0006 | 50S |
| |
|
| 0007 | 1min |
| |
|
| 0008 | 2min |
| |
|
|
|
|
| |
401 | SRC PROTECT |
|
| For setting the tape protection mode operation when the unit has been left | |
|
|
|
| in the STILL mode. | |
|
| 0000 | STEP | 0: STEP FWD | |
|
| 0001 | HALF | 1: STANDBY OFF (half loading) | |
|
|
|
| <Note> | |
|
|
|
| When STEP FWD has been set, the unit is automatically transferred to the | |
|
|
|
| STANDBY OFF (half loading) mode when it has been left in the STILL | |
|
|
|
| mode for a total of 30 minutes. | |
|
|
|
|
| |
402 | DRUM STDBY |
|
| For setting the drum operation in the STANDBY OFF (half loading) mode. | |
|
| 0000 | OFF | 0: The drum stops rotating. | |
|
| 0001 | ON | 1: The drum continues to rotate. | |
|
|
|
|
| |
403 | STOP PROTECT |
|
| For setting the tape protection mode operation when the unit has been left | |
|
|
|
| in the STOP mode. | |
|
| 0000 | STEP | 0: STEP FWD | |
|
| 0001 | HALF | 1: STANDBY OFF (half loading) | |
|
|
|
| <Note> | |
|
|
|
| When STEP FWD has been set, the unit is automatically transferred to the | |
|
|
|
| STANDBY OFF (half loading) mode when it has been left in the STOP | |
|
|
|
| mode for a total of 30 minutes. | |
|
|
|
|
|
The underlining denotes the factory mode.
29