Setup Menus

INTERFACE

 

Item

 

Setting

 

 

 

 

 

 

 

Description of setting

No.

Superimposed

No.

Superimposed

 

 

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

202

ID SEL

 

 

For setting the ID information to be returned to the controller.

 

 

0000

OTHER

0: 20 25H is returned.

 

 

0001

DVCPRO

1: The ID

(F0 33H) unique to the DVCPRO is returned.

 

 

0002

ORIG

2: The ID

(A0 51H) unique to the unit is returned.

 

 

 

 

 

 

The underlining denotes the factory mode.

TAPE PROTECT

 

Item

 

Setting

 

 

 

 

 

Description of setting

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

STILL TIMER

0000

0.5S

For setting the time taken before the unit is set to the tape protection mode

 

 

0001

5S

when it has been left in the STOP or STILL mode.

 

 

0002

10S

(Unit: S = seconds, min: minutes)

 

 

0003

20S

 

 

 

0004

30S

 

 

 

0005

40S

 

 

 

0006

50S

 

 

 

0007

1min

 

 

 

0008

2min

 

 

 

 

 

 

401

SRC PROTECT

 

 

For setting the tape protection mode operation when the unit has been left

 

 

 

 

in the STILL mode.

 

 

0000

STEP

0: STEP FWD

 

 

0001

HALF

1: STANDBY OFF (half loading)

 

 

 

 

<Note>

 

 

 

 

When STEP FWD has been set, the unit is automatically transferred to the

 

 

 

 

STANDBY OFF (half loading) mode when it has been left in the STILL

 

 

 

 

mode for a total of 30 minutes.

 

 

 

 

 

402

DRUM STDBY

 

 

For setting the drum operation in the STANDBY OFF (half loading) mode.

 

 

0000

OFF

0: The drum stops rotating.

 

 

0001

ON

1: The drum continues to rotate.

 

 

 

 

 

403

STOP PROTECT

 

 

For setting the tape protection mode operation when the unit has been left

 

 

 

 

in the STOP mode.

 

 

0000

STEP

0: STEP FWD

 

 

0001

HALF

1: STANDBY OFF (half loading)

 

 

 

 

<Note>

 

 

 

 

When STEP FWD has been set, the unit is automatically transferred to the

 

 

 

 

STANDBY OFF (half loading) mode when it has been left in the STOP

 

 

 

 

mode for a total of 30 minutes.

 

 

 

 

 

The underlining denotes the factory mode.