Power supply:

100 V to 240 V AC, 50/60 Hz

Power consumption: 170 W

(Without CAMERA connected: 32 W)

Capacity for supplying power to a camera: 190 V DC, 0.6 A

indicates safety information.

Operating temperature:

0 °C to 40 °C (32 °F to 104 °F)

Humidity:

10 % to 90 % (no condensation)

Dimensions (Width × Height × Depth): 424 mm × 88 mm × 400 mm

(16-11/16 inches × 3-7/16 inches × 15-3/4 inches) [Excluding protrusions]

Weight:

Approx. 6.6 kg (14.6 lb)

Video output:

HD-SDI/SD-SDI

4lines (2 lines shared with picture monitor output *2) Analog composite

1 line (1 line shared with picture monitor output *2)

Return input:

HD-SDI/SD-SDI (switched depending on the setting) 2 lines

VBS 1 line

Prompter input: Analog composite

1 line

Reference input:

Black burst/tri-level *1

1 line (1 loop-through line)

Microphone output: 0 dBm/600 Ω

2 lines (XLR, 3-pin, male)

Intercom:

Input: –55 dBu to –10 dBu

Output: 100 mW (max.) (XLR, 5-pin, female)

COMMUNICATION: Intercom input/output:

(0 dBm, 600 Ω, RTS/4W *2)

2 lines (1/2 *2)

PGM input (0 dBm/600 Ω) 1 line

Tally input (red, green) 1 input each

ROP interface: RS-422

1 line, 12 V output

MSU interface: RS-422

1 line, GPI for control

LAN port:

For computer connection

1 line (10Base-T/100Base-TX, RJ45, crossover cable, category 5 or above)

*1: The black burst signal and tri-level sync signal of the reference input are recognized automatically.

*2: Depending on the setting, only one of them can be selected at one time.

Note

For details on the maximum lengths of connection cables, consult your dealer.

Inrush current, measured according to European standard EN55103-1, on initial switch-on: 7 A, after a supply interruption of 5 s: 11 A