Main Menu (continued)

SYSTEM CONFIG

 

 

 

The underlined values are factory preset setting values.

Sub menu

Settings

Explanation

 

CONT. /BACK.

BACKLIGHT

Used to select the function to be assigned to CONT/B.LIGHT (a knob

 

CONTRAST

on the front panel).

 

 

<BACKLIGHT> Used to adjust BACKLIGHT.

 

 

<CONTRAST> Used to adjust CONTRAST.

BACKLIGHT

0 - 60

Used to adjust the LCD backlight level.

 

 

<Note>

 

 

 

CONT./BACK displays “-” while BACKLIGHT settings are performed.

PEAKING/PHASE

PEAKING

Used to select the function to be assigned to PEAK/PHASE (a knob

 

PHASE

on the front panel).

 

 

<PEAKING>

Assigns to the PEAKING function.

 

 

<PHASE>

Assigns to the PHASE function.

STATUS DISPLAY

CONTINUE

Used to set the display time for the status display.

 

3SEC OFF1

<CONTINUE> Always displayed.

 

OFF

<3SEC OFF>

Displayed for 3 seconds.

 

 

<OFF>

Not displayed.

BATTERY REMAIN

OFF

Used to select whether or not to display the battery level.

 

ON

<OFF> Not displayed.

 

 

<ON> Displayed.

SETUP LOAD

FACTORY

Used to load the saved factory preset setting values (FACTORY) or

 

USER1

user data (USER 1 - USER 5).

 

USER2

<FACTORY> The factory preset settings.

 

USER3

<USER1 - 5> The saved USER data 2.

 

USER4

When the unit is shipped from the factory, the USER 1 to 5 data items

 

USER5

are the same as the factory preset values.

SETUP SAVE

USER1

Used to save user data.

 

USER2

Up to 5 sets of user data can be saved, which include the current

 

USER3

setting values for the menu and picture adjusting knobs.

 

USER4

 

 

 

USER5

 

 

PWR ON SETUP

LAST

Used to select the settings for when the power supply is switched

 

FACTORY

ON.

 

 

USER1

<LAST>

Starts up with same settings as the last time the power

 

USER2

 

supply was switched OFF.

 

USER3

<FACTORY> Starts up with the FACTORY settings.

 

USER4

<USER1 - 5> Starts up with the settings that are saved in a USER

 

USER5

 

item.

1 Functions as CONTINUE when (warning of improper operation status for the camera settings) is displayed or when the P-P(PIXEL TO PIXEL) status is displayed.

2 USER saving is not possible when CONTROL is set to REMOTE.

21

Page 11
Image 11
Panasonic BT-LT80W manual System Config