•Multi split combination possibility:
o A single outdoor unit enables air conditioning of up to two separate rooms for
|
|
|
|
|
|
|
|
|
|
|
|
|
| Outdoor Unit | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A |
| B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wall |
|
|
| 2.8 kW |
|
|
|
|
|
|
| ● |
| ● | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 3.2 kW |
|
|
|
|
|
|
| ● |
| ● | |||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Capacity range of connectable indoor units |
|
|
|
|
| From 5.6 kW to 6.4 kW |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 1 room maximum pipe length (m (ft)) |
|
|
|
|
| 25 (82.0) |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Length | Allowable elevation (m (ft)) |
|
|
|
|
| 15 (49.2) |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Total allowable pipe length (m (ft)) |
|
|
|
|
| 50 (164.0) |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||||||
Piping |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total pipe length for maximum chargeless length (m (ft)) |
|
|
| 20 (65.6) |
|
|
|
| ||||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Additional gas amount over chargeless length (g/m (oz/ft)) |
|
|
| 20 (0.2) |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Note: “●” : Available | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Remarks for |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 1. | At least two indoor units must be connected. |
|
|
|
|
|
|
|
|
|
| ||||
| 2. | The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of | ||||||||||||||
|
| indoor unit. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| (as shown in the table above) |
|
|
|
|
|
|
|
|
|
|
| |||
|
| Example: The indoor units’ combination below is possible to connect to | ||||||||||||||
|
| between 5.6 kW to 6.4 kW) |
|
|
|
|
|
|
|
|
|
|
| |||
|
| 1) Two |
|
|
|
|
|
|
| |||||||
|
| 2) One |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Indoor unit combination | Operation | Capacity (kW) | Input Power (W) | Current (A) | Current (A) |
| Moisture | ||||||
Outdoor Unit |
|
|
| Mode |
|
|
|
|
| 208V |
| 230V |
| Removal | ||
|
|
| Operation |
| Class (kW) | Rating |
| Min - Max | Rating | Min - Max | 60Hz |
| 60Hz | Volume (L/h) | ||
|
|
|
|
|
|
| ||||||||||
|
|
|
| 2.8 | Cooling | 2.82 |
| 1.81 ~ 3.27 | 850 | 390 ~ 1020 | 4.5 | 4.1 | 0.5 | |||
|
|
| Operation |
| 3.2 | 3.21 |
| 1.85 ~ 3.75 | 1000 | 390 ~ 1230 | 5.2 | 4.7 | 0.6 | |||
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 2.8 + 2.8 |
| 4.89 |
| 2.09 ~ 5.86 | 1450 | 390 ~ 1920 | 7.6 | 6.9 | 0.5 + 0.5 | ||||||
|
|
|
|
| Cooling |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 2.8 + 3.2 | 4.89 |
| 2.10 ~ 5.86 | 1450 | 390 ~ 1870 | 7.6 | 6.9 | 0.5 + 0.6 | ||||
|
|
| Operation |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 3.2 + 3.2 |
| 4.89 |
| 2.10 ~ 5.86 | 1450 | 390 ~ 1840 | 7.6 | 6.9 | 0.6 + 0.6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| Indoor unit combination | Operation | Capacity (BTU/h) | Input Power (W) | Current (A) | Current (A) |
| Moisture | ||||||
Outdoor Unit |
|
|
| Mode |
|
|
|
|
| 208V |
| 230V |
| Removal | ||
|
|
| Operation |
| Class (kW) | Rating |
| Min - Max | Rating | Min - Max | 60Hz |
| 60Hz | Volume (Pt/h) | ||
|
|
|
|
|
|
| ||||||||||
|
|
|
| 2.8 | Cooling | 9600 |
| 6200 ~ 11200 | 850 | 390 ~ 1020 | 4.5 | 4.1 | 1.1 | |||
|
|
| Operation |
| 3.2 | 10900 |
| 6300 ~ 12800 | 1000 | 390 ~ 1230 | 5.2 | 4.7 | 1.3 | |||
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 2.8 + 2.8 |
| 16700 |
| 7100 ~ 20000 | 1450 | 390 ~ 1920 | 7.6 | 6.9 | 1.1 + 1.1 | ||||||
|
|
|
|
| Cooling |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 2.8 + 3.2 | 16700 |
| 7200 ~ 20000 | 1450 | 390 ~ 1870 | 7.6 | 6.9 | 1.1 + 1.3 | ||||
|
|
| Operation |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 3.2 + 3.2 |
| 16700 |
| 7200 ~ 20000 | 1450 | 390 ~ 1840 | 7.6 | 6.9 | 1.3 + 1.3 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
•Specifications are subject to change without notice for further improvement.