To learn more...
Operation mode
AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects operation mode during startup according to setting temperature and room temperature.
COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
nanoe-G in-filter deactivation
Depending on the unit’s accumulated operation time,
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly. This process only applicable when the unit is operated in COOL/DRY mode before turned off. Then,
Do not turn off the power supply during this operation. After power failure, this operation will not resume.
ECONAVI and AUTO COMFORT
AUTO
ECONAVI or COMFORT
The unit will start to initialise | The human activity sensor |
(for approximately 1 minute) | and the sunlight sensor will |
| start to detect. |
Note
AIR SWING When manual AIR SWING is selected, the ECONAVI and AUTO COMFORT operations will be cancelled.
Human activity sensor operation
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode | Human | Low activity | Normal activity | High activity | Absent |
|
| +1 °C |
|
| +2 °C |
COOL/DRY | Set |
|
|
| |
|
|
|
| ||
temperature |
|
|
|
| |
|
|
|
|
|
AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human comfortable consistently.
Mode | Human | Low activity | Normal activity | High activity | Absent |
|
| +1 °C |
|
| +2 °C |
| Set |
|
|
| |
|
|
|
|
| |
COOL/DRY | temperature |
|
|
| |
|
|
|
| ||
|
|
|
| ||
|
|
|
|
| |
| Set | +1 tap* |
| +1 tap | ≤Medium Fan** |
| Fan Speed |
|
|
| |
|
|
|
|
|
ECONAVI and AUTO COMFORT
Precise control of temperature during low activity to maximise energy saving.
Mode |
| Human |
| Low activity | |||
COOL/DRY |
| Set |
|
|
|
|
|
|
|
|
|
|
| ||
|
| temperature |
|
|
|
|
|
|
|
|
|
|
|
|
ECONAVI and AUTO COMFORT take advantage of the human nature that human being takes time to feel the temperature rise during low activity level; the unit adjusts temperature to maximise energy saving without sacrificing the comfort.
*During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
**During human absence, maximum fan speed for COOL/DRY mode is medium fan.
18
1/17/2013 10:10:08 AM