The human activity sensor will also scan for area of heat source and movement in a room.
Detection area | Human activity indicator |
120º
7m
At left area | At center / multiple area |
At right area
The unit judges human activity area for a few seconds before indicator updates. Based on area activeness horizontal airflow direction louver will adjust either fix at predetermined position or swing left/right periodically.
•The human activity sensor performance is influenced by indoor unit location, movement speed, temperature range, etc.
•The human activity sensor may:
-mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
-mistakenly detect as
•Do not place large objects near the sensor and keep away heating units or humidifier from the sensor’s detection area. They may cause sensor malfunction.
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Mode | Ambient condition | |
| ||
| +1 °C | |
COOL/DRY | Set | |
temperature | ||
|
ECONAVI is activated, the unit maintains set temperature until a high sunlight intensity is detected. The sunlight sensor detects sunlight intensity during weather or day/night changes, and the unit adjusts temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C) |
|
| Indoor |
| Outdoor | |||
| DBT |
| WBT | DBT |
| WBT | ||
|
|
|
|
| ||||
COOL |
| Max. | 32 |
| 23 | 55 |
| 31 |
| Min. | 16 |
| 11 | 16 |
| 11 | |
|
|
|
|
English To learn more...
19