9 Measurements and Adjustments
9.1.Matrix Chart for Replaced Part and Necessary Adjustment
The relation between Replaced part and Necessary Adjustment is shown in the following table. When concerned part is replaced, be sure to achieve the necessary adjustment(s).
As for Adjustment condition/procedure, consult the “Adjustment Manual” which is available in Adjustment software.
The Adjustment software is available at “TSN Website”, therefore, access to “TSN Website” at “Support Information from NWBG/
NOTE:
After adjustments have been terminated, make sure to achieve “INITIAL SETTINGS”.
|
|
|
| Replaced Part |
|
|
|
| Main P.C.B. | VENUS | Lens Part | CCD Unit | |
| Adjustment Item |
| (IC6001) | (IC6002) | (Excluding |
|
|
|
|
|
| CCD) |
|
|
|
|
|
|
|
|
Camera | OIS hall element adjustment | O | O | O | O |
|
Section | (OIS) |
|
|
|
|
|
|
|
|
|
|
|
|
| Back focus adjustment | O | O | O | O |
|
| (BF) |
|
|
|
|
|
|
|
|
|
|
|
|
| Shutter adjustment | O | O | O | O | O |
| (SHT) |
|
|
|
|
|
|
|
|
|
|
|
|
| ISO sensitivity adjustment | O | O | O | O | O |
| (ISO) |
|
|
|
|
|
|
|
|
|
|
|
|
| AWB adjustment | O | O | O | O | O |
| High brightness coloration inspection |
|
|
|
|
|
| (WBL) |
|
|
|
|
|
|
|
|
|
|
|
|
| CCD white scratch compensation | O | O | O |
| O |
| (WKI) |
|
|
|
|
|
|
|
|
|
|
|
|
NOTE:
*There is no LCD adjustment in this model.
*There is no CCD Black scratch compensation adjustment (BKI) in this model.