7.2.When Replacing the Main PCB

After replacing the MAIN PCB, be sure to achieve adjustment.

The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in “TSN system”, together with Maintenance software.

7.3.Service Position

This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.

 

 

Table S1 Extension Cable List

 

 

 

 

 

No.

Parts No.

Connection

Form

1

VFK1950

FP9801 (MAIN) - CCD UNIT

33PIN 0.3 FFC

2

RFKZ0416

FP9802 (MAIN) - LENS UNIT

41PIN 0.3 FFC

 

 

 

 

3

RFKZ0363

FP9803 (SUB) - FP9901 (FLASH)

19PIN 0.5 FFC

4

RFKZ0363

FP9005 (MAIN) - FP8001 (TOP OPERATION)

19PIN 0.5 FFC

 

 

 

 

5

RFKZ0363

FP9001 (MAIN) - LCD UNIT (For DMC-TZ3)

19PIN 0.5 FFC

 

 

FP9002 (MAIN) - LCD UNIT (For DMC-TZ2)

 

6

VFK1974

FP9003 (MAIN) - LCD UNIT (For DMC-TZ3)

4PIN 0.5 FFC

 

 

 

 

 

 

FP9004 (MAIN) - LCD UNIT (For DMC-TZ2)

 

7

RFKZ0362

PS9801 (SUB) - PP9001 (MAIN)

100PIN B to B

 

 

 

 

7.3.1.Extension Cable Connections for DMC-TZ3

20

Page 20
Image 20
Panasonic DMC-TZ3EB, DMC-TZ3EE, DMC-TZ3PC manual When Replacing the Main PCB, Service Position