7.2.When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from
7.3.Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
|
| Table S1 Extension Cable List |
|
|
|
|
|
No. | Parts No. | Connection | Form |
1 | VFK1950 | FP9801 (MAIN) - CCD UNIT | 33PIN 0.3 FFC |
2 | RFKZ0416 | FP9802 (MAIN) - LENS UNIT | 41PIN 0.3 FFC |
|
|
|
|
3 | RFKZ0363 | FP9803 (SUB) - FP9901 (FLASH) | 19PIN 0.5 FFC |
4 | RFKZ0363 | FP9005 (MAIN) - FP8001 (TOP OPERATION) | 19PIN 0.5 FFC |
|
|
|
|
5 | RFKZ0363 | FP9001 (MAIN) - LCD UNIT (For | 19PIN 0.5 FFC |
|
| FP9002 (MAIN) - LCD UNIT (For |
|
6 | VFK1974 | FP9003 (MAIN) - LCD UNIT (For | 4PIN 0.5 FFC |
|
|
|
|
|
| FP9004 (MAIN) - LCD UNIT (For |
|
7 | RFKZ0362 | PS9801 (SUB) - PP9001 (MAIN) | 100PIN B to B |
|
|
|
|
7.3.1.Extension Cable Connections for
20