EY7440-U1 /
Ref. No. 2G | Procedure 2A → 2B → 2C→ 2D→ 2E→ 2F→ | Attachment of the Housing. | |
| 2G |
|
|
|
| 1. | Place the driving block onto the housing A and place the spring |
|
| for release lever and the hook release lever. | |
| 2. | Place the switch assembly, operation panel, click spring and F/R | |
|
| selector handle onto the housing A. | |
|
| NOTE : | |
|
|
| Make sure that the lead wires are pressed fit firmly. |
| 3. | Close the housing A and B with pushing the radiating plate on the | |
|
| direction of the arrow and tighten 8 housing screws. | |
|
| NOTE : | |
|
|
| Confirm to set the radiating plate properly. If the radiating plate |
|
|
| lean toward the motor brush side, the housing B can not be |
|
|
| closed. |
| 4. | Place the H/L change handle into the rail properly. | |
| 5. | Insert the belt hook into the housing and tighten with hook bolt. | |
|
|
|
|
8