Panasonic manual FBA06A 60X 25.5L, Allowable Ambient Temperature Range, Failure Rate 10%

Models: FBA06A

1 1
Download 1 pages 23.73 Kb
Page 1
Image 1
 FBA06A (60X 25.5L)

Allowable Ambient Temperature Range: FBA06A (60Failure Rate: 10%X 25.5L)

EMINEBEA.COM

Allowable Ambient Temperature Range:

-10°C ~ +70°C (65%RH) (Operating) -40°C ~ +75°C (65%RH) (Storage) (non-condensing environment)

Failure Rate: 10%

50,000 Hours (40°C, 65%RH)

Units:

inch

(mm)

.157

 

ROTATION

4 – (f4.0)

 

2.36

(60)

1.97

(50)

 

 

 

1.97

 

 

 

(50)

 

 

 

2.36

 

 

 

(60)

.165

4 – (f4.2)

 

 

 

 

 

 

 

 

2.28

(58)

1.97

(50)

.36

2

(f65)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.97

(50)

2.28

(58)

INLET SIDE

1.00

(25.5)

inlet

outlet

NAME PLATE

 

&,/7

 

- Pin

 

 

+ Pin

.165

4 – (f4.2)

 

 

 

 

 

 

 

 

2.28

(58)

1.97

(50)

.36

2

(f65)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.97

(50)

2.28

(58)

OUTLET SIDE

 

In H2O

(Pa)

 

 

 

 

(min-1)

 

 

.23

60

 

 

 

6000

 

PressureStatic

 

 

 

12V(24V)-H

 

 

 

SpeedNormal

 

 

 

 

 

 

 

 

.15

40

 

 

12V(24V)-M

4000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12V(24V)-L

 

Ps .07

20

 

 

 

2000

N

 

 

0

0.2

0.4

0.6

(m3/min)

 

 

 

 

 

 

 

 

 

10

 

20

(CFM)

 

 

 

 

 

 

 

 

Air Flow

Bearing: Hydro Wave Bearing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

Rated

Operating

Current

Input

Rated

 

Max.

Max. Static

Noise

Mass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Voltage

 

 

Power

Speed

Air

 

Flow

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(V)

(V)

 

(A)*1

(W)*1

(min-1)*1

CFM*1

 

(m3/min)*1

in H2O

(Pa)*1

(dB)*1

(g)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FBA06A 12L

12

7.0 ~ 13.8

100

1.20

3200

14.1

 

0.40

.12

30.4

24.0

90

 

 

 

 

 

 

 

FBA06A 12M

12

7.0 ~ 13.8

120

1.44

3700

16.6

 

0.47

.15

38.7

28.0

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FBA06A 12H

12

7.0 ~ 13.8

155

1.86

4200

19.1

 

0.54

.20

51.0

32.0

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FBA06A 24L

24

14.0 ~ 27.6

60

1.44

3200

14.1

 

0.40

.12

30.4

24.0

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FBA06A 24M

24

14.0 ~ 27.6

70

1.68

3700

16.6

 

0.47

.15

38.7

28.0

90

 

 

 

 

 

 

 

FBA06A 24H

24

14.0 ~ 27.6

85

2.04

4200

19.1

 

0.54

.20

51.0

32.0

90

 

 

 

 

 

 

 

Rotation: Clockwise

 

 