XxxxxFP2/FP2SHXxxxxxxx

XxxxxSpecificationsXxxxxxxx

CPU units

 

 

 

 

FP2 CPU unit

 

FP2SH CPU unit

 

 

Item

 

FP2-C1

 

 

 

 

 

 

 

 

FP2-C1D

FP2-C2

 

FP2-C2P

FP2-C3P

 

 

 

 

FP2-C1SL

 

 

 

 

Operation speed

Basic

 

0.35s or more

 

0.03s or more

 

High-level

 

0.93s or more

 

0.06s or more

 

 

 

 

 

Program capacity

Built-in RAM

 

16k steps

60k steps

 

120k steps

With expansion

32k steps

Not available

 

Not available

 

 

 

No expansion

 

Conventional type

Max. 768 points

 

Max. 768 points

 

 

 

H type

Max. 512 points

 

Max. 512 points

 

Number of I/O points

With expansion

 

Conventional type

Max. 1600 points

 

Max. 1600 points

 

 

 

 

 

 

 

H type

Max. 2048 points

 

Max. 2048 points

 

 

 

 

 

 

 

With remote I/O

Max. 2048 points

 

Max. 8192 points

 

 

Internal relay

4048 points

 

14,192 points

 

 

Data register

6000 words

 

10,240 words

 

Operation memory

File register

 

0 to 143,333 words

 

32,765 words x 3 banks

 

 

 

(w/expansion 0 to 30,717 words)

 

 

 

 

 

 

 

 

 

 

 

Link register

 

256 words

 

 

8448 words

 

Optional memory

 

 

 

F-ROM/EP-ROM

F-ROM/EP-ROM

 

Small PC card (F-ROM/S-RAM)

Comment memory

 

 

 

Optional memory unit

 

 

Available

 

Clock/Calendar function

 

Optional memory unit

 

 

Available

 

 

 

 

 

 

 

 

 

 

Power supply units

 

Item

FP2-PSA1

 

FP2-PSA2

FP2-PSA3

FP2-PSD2

 

Rated voltage

100V - 120VAC

 

200V - 240V

100V - 240VAC

24VDC

 

Current consumption

0.4A or less (at 100VAC)

 

0.2A or less (at 200VAC)

0.7A or less (at 100VAC) 0.4A or less (at 200VAC)

2.5A or less

Input

Surge current

40A or less (55°C)

30A or less (25°C)

10A or less

 

Rated frequency

 

 

47Hz ~ 63Hz

 

 

Operating

85 to 132VAC

 

170 to 264VAC

85 to 264VAC

20.4 to 31.2VDC note)

Output

Voltage range

 

2.5A max.

5A max.

Alarm contact capacity

 

 

30VDC 1A

 

Alarm contact operation

 

 

When the ALARM LED of CPU unit is lit

 

Alarm contact type

 

 

1c contact

 

Leakage current

 

 

Between input and ground terminals, 0.75mA or less

 

Breakdown voltage

 

 

1500VAC for 1 minute (between input and ground terminals)

 

Insulation resistance

 

 

100 M500VDC (between input and ground terminals)

 

Guaranteed lifetime

 

 

20,000 hours at 55°C

 

Overcurrent protection function

 

 

Built-in overcurrent protection

 

Fuse

 

 

 

Built-in type

 

Terminal screw

 

 

 

M3

 

Module size

1 modul

 

1 modul

2 module

2 module

 

 

 

 

 

 

 

Note: Allowable voltage fluctuation range after startup for the FP2-PSD2 is -35% to +30%. At startup, apply -15% to + 30% the rated voltage for 100ms or more.

18

08/2007

Page 18
Image 18
Panasonic manual XxxxxFP2/FP2SHXxxxxxxx, XxxxxSpecificationsXxxxxxxx,  Power supply units, Rom/Ep-Rom