Analog Control

Accurate Process Control

Analog control

Multi-range control of a variety of equipment is possible. The units can be directly connected with thermocouples and resistance temperature detectors

Support voltage/current/temperature sensor ranges

The analog input unit supports voltage, current, and temperature sensors. The analog output unit supports voltage or current output.

Different voltage/current ranges can be controlled concurrently.

Equipped with multiple channels

The input unit has eight channels, and the output unit has four. Space-saving multiple-channel control is possible.

High-speed conversion at 500ms by each channel

The speed of voltage and current input/output conversion can reach as high as 500ms.

I/O refresh system

Since input/output data is allocated to the I/O memory, complicated programming is not necessary.

Configuration

Current input

Laser analog sensor

Current input

Pressure sensor

Analog input unit

Analog output unit

Voltage

output Inverter

(speed command)

Analog input units

Three types of analog input units are available to meet a wide variety of customer needs.

High-speed, high-accuracy, multiple-input unit with 8 isolated channels

Industry‘s fastest level

High-speed achieved by highly reliable isolation among channels

Temperature conversion:

20ms/ch

Voltage conversion:

5ms/ch

(Without insulation setting:

500ms/ch)

Industry‘s top level

 

High-accuracy conversion

 

Voltage: ±0.1% (25°C)

 

Temperature: ±0.3% (0 to 55°C)

 

Multiple inputs

 

A single unit supports inputs of

FP2-AD8X

thermocouple, RTD, and voltage data*1.

 

For users who require faster and more accurate temperature control.

For users who require multiple isolated input channels or who want to reduce the cost per channel.

For users who want to input tempera- ture and voltage (current) data through a single unit.

*1: Current inputs can be converted into voltage in- puts by attaching the supplied external resistor to the input terminal section.

 

 

 

 

Analog output unit

8 inputs unit solely for

 

8 low costs inputs solely

Supports multiple channels.

RTDs (Pt100/Pt1000)

 

for voltage/current data

(Four channels per unit).

 

 

 

 

 

High-speed, high-accuracy

 

High-speed, high-accuracy

 

High-speed, high-accuracy

Conversion speed: 20ms/ch

 

Low cost unit for input of voltage/

Number of outputs: 4

Conversion accuracy: ±0.3%

 

current data that indicates mea­

Conversion speed: 500ms/ch

(0 to 55°C)

 

surements of pressure, flow rate,

Overall accuracy: ±1.0% FS

For users who input RTD data only

 

fluid volume, speed, etc.

or less

 

 

 

(0 to 55°C)

and require more affordable type.

 

 

 

 

 

 

 

FP2-RTD

 

FP2-AD8VI

FP2-DA4

 

08/2007

 

 

 

 

 

Page 6
Image 6
Panasonic FP2 manual Analog Control, Accurate Process Control,  Analog control,  Analog input units,  Analog output unit