FPΣ (Sigma)

Optimised communication functions

1-channel RS232C type.

2-channel RS232C type.

1-channel RS485 type.

1-channel RS232C + 1-channel RS485 type.

With the RS485 type communication cassette...

Four types of communication cassettes enable:

efficient connection to serial devices

transmission speeds of up to 115.2kbits/s

long transmission distance of up to 1200m

In addition, the green screw terminal is removable for easy wiring.

Despite being compact you can create powerful PLC links!

More links than you imagined a compact PLC could achieve (2,048 link relays / 256-word link data registers)

Can be used to share product type between different machines. Can be used for interlocking between different machines.

Easy wiring between PLCs with twin-core cabling.

Link data register

Product type data

Process machine

Link data register

Product type data

Assembly

machine

Link data register

Product type data

Inspection

machine

RS485

Masterless communication method

(when PLC linkage is achieved with link relays and link data registers)

The masterless communication method means that even if a connected device (station) goes into power off, operations to automatically switch the master station continue. Start up is smooth and the recovery from malfunctions is also potentially faster.

Previous models

Usual master-slave communication

If the master station is not on, communication cannot take place.

Errors occur when devices are not turned on in sequence.

Master station

Slave

Slave

Slave

Slave

station

station

station

station

Use of insulated RS485

With the FPΣ (Sigma)

Masterless communication using the FPΣ (Sigma)

Even if a station goes into a power- off state, communications between the other stations continue.

Link

Link

Link

Link

station

station

station

station

Uses the insulated RS485, which is highly reliable and largely impervious to noise. High-speed communication over long distances are enabled.

Transmission speed: Max. 115.2kbits/s

Transmission distance: Max. 1.200m