SPECIFICATIONS

1) Ratings

Operating side

Rated operating voltage

12 to 24 V DC

Rated current consumption

30 mA or less (excluding load)

 

Load side

Output current capacity

100 mA or less

 

 

 

2) Performance

Detection principle

Triple beam triangulation sensing method

Detection method

 

 

 

Area reflective type

 

Type

 

 

 

Amplifier selfcontained DC type

 

 

 

 

MQ-W3A-DC12-24V

 

MQ-W20A-DC12-24V

 

 

Part number

 

MQ-W3AR-DC12-24V

 

MQ-W20AR-DC12-24V

 

MQ-W70A-DC12-24V

 

MQ-W3C-DC12-24V

 

MQ-W20C-DC12-24V

 

MQ-W70C-DC12-24V

 

 

 

 

 

 

 

 

MQ-W3CR-DC12-24V

 

MQ-W20CR-DC12-24V

 

 

Sensing range

 

0.03 m .098 ft.

 

0.2 m .656 ft.

 

0.7 m 2.297 ft.

Detectable distance

0.02 to 0.04 m .066 to .131 ft.

 

0.04 to 0.2 m .131 to .656 ft.

 

0.2 to 0.7 m .656 to 2.297 ft.

Standard target

 

White drawing paper

 

White drawing paper

 

White drawing paper

 

1 1 cm .394 .394 inch

 

2 2 cm .787 .787 inch

 

7.5 7.5 cm 2.953 2.953 inch

 

 

 

 

 

Detectable target

 

 

 

Opaque, translucent

 

Hysteresis

 

10% or less the set range

 

20% or less of the set range

Operating voltage range

 

9.6 to 30 V DC ripple (P-P) included

 

Response time (freq.)

2 ms or less (250 times per second or less)

Initial insulation resistance

Min. 20 MΩ between a lead wire and external housing (at 500 V DC)

Initial breakdown voltage

Between a lead wire and external housing: 500 Vrms for 1 min

Vibration resistance

10 to 55 Hz (1 cycle/min), double amplitude 1.5 mm .059 inch (2 h each on 3 axes)

Shock resistance

 

980 m/s2 {approx. 100 G} (6 times each on 3 axes)

Protective construction

Diecast case immersion protected (equivalent to IEC IP67)

Usable ambient

 

Incandescent lamp

 

 

10,000 lux or less

 

light level

 

Sunlight

 

 

30,000 lux or less

 

 

 

 

 

 

Ambient temperature

–25 to 55°C –13 to +131°F (non-icing condition)

Ambient humidity

 

Max. 85% RH (non-condensing condition)

Storage temperature

 

 

–25 to 55°C –13 to +131°F

 

Indicator

 

Operation indicator: Red LED ON with light entry

 

Adjustment indicator: Red LED ON with sufficient volume of lights

 

 

 

Light source

 

Infrared LED/Red LED (R is added to the suffix of W3(20)A(C) in the part No.)

 

 

 

 

 

 

 

 

Note: Unless otherwise specified, the measurement conditions comprise rated operating voltage, power supply by battery, 20°C 68°F ambient temperature, standard target and 200 lux or less illuminance on the receiver surface.

3) Output circuit diagram

NPN Output type

PNP Output type