How to Operate

D. PROGRAMMING DOUBLE OR TRIPLE QUANTITY PAD

The oven can not be programmed when Program Lock is activated! (see page 11-12)

DO NOT OPEN THE DOOR WHILE PROGRAMMING!

Example:  To program 1.5 times of heating time for double quantity into Number/Memory pad “5”

PAD

INSTRUCTION

DIGITAL DISPLAY WINDOW

1Keep the door closed.

Digital Display Window must be blank.

2

 

PROG

Press Prog pad.

PROG

 

 

 

“PROG” will start to blink.

 

3

 

5

Press Number/Memory pad “5”.

PROG

 

 

The selected pad number will appear and currently programmed

1

 

 

 

information will be indicated.

 

 

 

 

HI

4

 

x 2

Press Double Quantity pad.

PROG

 

 

 

The currently programmed magnification number will appear.

 

 

 

 

Note:  1.6 times is preset at factory.

 

5

1

5

Press Number/Memory pads “1” and “5” for 1.5 times.

 

 

The programmed magnification number will appear.

PROG

 

 

 

If pad 5 is programmed for 3 minutes, the time for the double quantity

 

 

 

 

will be 4 minutes and 30 seconds.

 

 

 

 

Available range is 0.1-5.0 times.

 

6

 

PROG

Press Prog pad.

PROG

 

 

 

“PROG” will stop blinking.

 

 

 

 

This means that you have completed programming.

 

• Three seconds later, Digital Display Window will go blank.

Note:

If you want to program your desired magnification number for triple quantity, repeat as above, using Triple

Quantity pad instead of Double Quantity pad.

E. PROGRAM LOCK

XXTo Activate Program Lock:

Example:  To program cooking at DEFROST power for 1 minute into Number/Memory pad “5”

1

2

PAD

INSTRUCTION

DIGITAL DISPLAY WINDOW

Keep the door closed.

Digital Display Window must be blank.

PROG

Press Prog pad until “PROG”, “P” and “L” appear. (more than five

PROG

seconds)

 

 

 

“PROG”, “P” and “L” will appear.

In Program Lock mode:

The oven is started by pressing the desired Number/Memory pad. There is no need to press Start pad.

Opening the door cancels the remaining time on the program.

The oven can not be programmed or run manually until the program lock is released.

- 11 -