>WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.
WARNING
1.This product should be serviced only by trained, qualified personnel.
2.Though this product has been manufactured in compliance with:
“Federal Performance Standard 21 CFR Subchapter J”(D.H.H.S): U.S.A. models
or “Radiation Emitting Devices Act”(Health and Welfare Canada): Canadian models
it is very important all repairs should be made in accordance with procedures described in this manual to avoid being exposed to excessive microwave radiation.
3.Check for radiation leakage before and after every servicing according to the “procedure for measuring radiation leakage.”
4.If the unit cannot be repaired on site, advise the customer not to use until unit is repaired.
5.Any serviceman who learns of any accident pertaining to microwave radiation leakage including the oven operating with open door should immediately notify the appropriate address listed below and Center for Devices and Radiological Health, DHHS.
IN U.S.A. | Panasonic Services Company | IN PUERTO RICO | PSC |
(PASC) | 50 Meadowland Parkway, | (PSC) | San Gabriel Industrial Park |
| Secaucus, New Jersey 07094 |
| 65th Infantry Ave. Km.9.5 |
| Attention: Technical Service Division. |
| Carolina, Puerto Rico 00985 |
|
| ||
|
| IN CANADA | Panasonic Canada Inc. |
|
| (PCI) | 5770 Ambler Drive, Mississauga, |
|
|
| Ontario, L4W2T3 |
|
|
|
6. There are special components used in the microwave oven which are important for safety. These parts are marked with
a> on the replacement parts list. It is essential that these critical parts should be replaced only with the manufacture’s specified parts to prevent microwave leakage, shock, fire, or other hazards. Do not modify the orginal design.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(A)Do not operate or allow the oven to be operated with the door open.
(B)Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary:
(1)Interlock operation
(2)Proper door closing
(3)Seal and sealing surfaces (arcing, wear, and other damage)
(4)Damage to or loosening of hinges and latches.
(5)Evidence of dropping or abuse
(C)Before turning on microwave power for any service test or
inspection within the microwave generating compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment, integrity and connections.
(D)Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and trans- mission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.
(E)A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner.
CONTENTS
| (Page) |
FEATURE CHART | 3 |
CONTROL PANEL | 3 |
OPERATION AND DIGITAL PROGRAMMER |
|
CIRCUIT TEST PROCEDURE | 5 |
SCHEMATIC DIAGRAMS | 7 |
DESCRIPTION OF OPERATING SEQUENCE | 9 |
CAUTIONS TO BE OBSERVED WHEN TROUBLESHOOTING .... | 11 |
(Page) | |
DISASSEMBLY AND PARTS REPLACEMENT PROCEDURE | 13 |
COMPONENT TEST PROCEDURE | 16 |
MEASUREMENTS AND ADJUSTMENTS | 18 |
PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE... | 19 |
TROUBLESHOOTING GUIDE | 20 |
EXPLODED VIEW AND PARTS LIST | 24 |
SCHEMATIC DIAGRAM & |
|
PARTS LIST OF DIGITAL PROGRAMMER CIRCUIT | 25 |