Panasonic NN-L530BF, NN-S560BF Procedure For Measuring Microwave Energy Leakage, Equipment

Models: NN-L530BF NN-S560WF NN-S560BF

1 36
Download 36 pages 25.15 Kb
Page 20
Image 20
PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE

PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE

WARNING

Check for radiation leakage after every servicing. Should the leakage be more than 2 mW/cm2 (1mW/cm2 for Canada) inform PASC, PSC, or PCI immediately.

After repairing or replacing any radiation safety device, keep a written record for future reference, as required by D.H.H.S. and Health and Welfare Canada regulation. This requirement must be strictly observed. In addition, the leakage reading must be recorded on the service repair ticket while in the customer’s home.

(B)Should the radiation leakage be more than 2 mW/cm2 (1mW/cm for Canada) after determining that all parts are in good condition, functioning properly, and genuine replacement parts as listed in this manual have been used, immediately notify PASC, PSC or PCI.

4.At least once a year, have the radiation monitor checked for calibration by its manufacturer.

NOTE: The U.S. Government standard is 5 mW/cm2 while in the customer’s home. 2mW/cm2 stated here is our own voluntary standard. (1mW/cm2 for Canada)

1. Equipment

*Electromagnatic radiation monitor *Glass thermometer 212 OF or 100 OC *600cc glass beaker

2. Procedure for measuring radiation leakage

Note before measuring.

(1)Do not exceed meter full scale deflection. Leakage monitor should initially be set to the highest scale.

(2)To prevent false readings the test probe should be held by the grip portion of the handle only and moved along the shaded area in Figure no faster than 1 inch/sec (2.5cm/sec).

(3)Leakage with the outer panel removed ...... less than 5mW/cm2 .

(4)Leakage for a fully assembled oven with door normally closed

...... less than 2mW/cm2 (1mW/cm 2for Canada).

(5)Leakage for a fully assembled oven [Before the latch switch (primary) is interrupted] while pulling the door ...... less than 2mW/cm2 .

(A)Pour 275￿15cc (9ozss￿1/2oz) of 20O￿5 OC (68O￿9 OF) water in a beaker which is graduated to 600cc, and place in the center of the oven.

(B)Set the radiation monitor to 2450MHz and use it following the manufacturer’s recommended test procedure to assure correct results.

(C)When measuring the leakage, always use the 2 inch (5cm) spacer supplied with the probe.

(D)Tap the start pad or set the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured.

(1)Measurement with the outer panel removed.

Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted. Special care should be taken in measur ing around the magnetron.

WARNING

Avoid contacting any high voltage parts.

(2)Measurements with a fully assembled oven.

After all components, including outer panel are fully assembled, measure for radiation leakage around the door periphery, the door viewing window, the exhaust opening and air inlet openings.

3. Record keeping and notification after measurement

(A)After any adjustment or repair to a microwave oven, a leakage read- ing must be taken. Record this leakage reading on the repair ticket even if it is zero.

A copy of this repair ticket and the microwave leakage reading should be kept by repair facility.

WARNING

AVOID CONTACTING ANY HIGH VOLTAGE PARTS.

01-035

MOVE PROBE ALONG SHADED

AREA(1. Equipment)AROUND EXHAUST

OPENINGS(as shown)AND AROUND

AIR INLET OPENING

- 19 -

Page 20
Image 20
Panasonic NN-L530BF Procedure For Measuring Microwave Energy Leakage, Equipment, Procedure for measuring radiation leakage