9.2.DEVELOPMENT OF APPLICATIONS
For software development the Insight DesktopTM, a comprehensive integrated
development environment (IDE) and
required. Insight DesktopTM is part of EmberTM development kits and can currently be purchased together with programming adaptors as EM250 jumpstart kit at a price of USD 2500,- directly from EmberTM Inc. (www.ember.com).
The environment works with the preceeding EM2420, the EM250 and the upcoming EM260. For code development it comprises the Integrated Development Environment (IDE) named xIDE based on eclipse 3.1.0 for editing, compiling and debugging of C– applications. In addition network visualization and debugging tools are included. For
PAN 4570 carrierboard. Before connecting PAN4570 to the EmberTM Insight Adaptor study the latest EmberTM Insight Adaptor documentation. The following pins of PAN4570 are connected to the signals on the debug connector of the EmberTMInsight adaptor:
PAN4570 | PAN4570 | Insight Adapter signal name |
pin | signal name |
|
various | ground | ground |
1(1) | VBAT | 3.0Vdc |
3 | RESET | RSTB |
25 | SIF_CLK | SIF_CLK |
26 | SIF_MISO | SIF_MISO |
27 | SIF_MOSI | SIF_MOSI |
28 | SIF_LOADB | SIF_LOADB |
as packet trace interface (PTI) also connect the following signals: | ||
10 | GPIO4 | GPIO4 |
11 | GPIO5 | GPIO5 |
(1)only if the EmberTM Insight Adaptor is set to powering the target device PAN4570
9.3.EMBERTM ZIGBEE STACK
EmberZNet (currently version 2.5.0) is the ZigBee stack provided with EM250. It supports as networking topologies true mesh, star and cluster networks. As ZigBee devices ZigBee Coordinator, ZigBee Full Fuctional Device and ZigBee End Devices are supported.
For the ease of application programming EmberZNet is controlled by the application over API commands. Direct ZigBee APS layer APIs are provided for applications that require low level ZigBee control.
According to [3] each ZigBee device has a unique address. This address has to be used by the device and is stored on the EM250 in PAN4570.
European Technology Center
Panasonic Electronic Devices (EUROPE) GmbH
APPROVED
genehmigt
CHECKED
geprüft
DESIGNED
Erstellt