Panasonic Pod9cw WJ-HD316A WU-CU650 Wiring Color Code, Power and Control Inputs, Cautions

Models: Pod9cw

1 8
Download 8 pages 28.29 Kb
Page 4
Image 4
WJ-HD316A

WJ-HD316A

WU-CU650

Wiring Color Code

Power and Control Inputs

POD9C

CONNECTOR A

CAMERA POWER [13 watts WV-CS954 / WV-CS574]

1

24 VAC Live

Black

2

24 VAC Live

White

3

Green

Green

4

Not Used

 

 

 

 

CONNECTOR B

ACCESSORY POWER [52 watts Heater/Blower]

1

24 VAC Live

Red

2

24 VAC Live

White

3

Green

Green

4

Not Used

 

 

 

 

Pan/Tilt Unit Only

 

How to assemble the connector

Strip back the cable jacket approximately 0.1 inch (3 mm) and separate the individual conductors.

 

 

 

 

Approx. 0.1"

Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up

 

 

 

 

 

 

 

 

 

 

 

 

 

Insert

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact

Prepare the individual conductors for clamping. If clamping, use Molex brand tool part number 57027- 5000 (for UL-listed-style cable UL1015) or 57026-5000 (for UL-listed-style cable UL1007).

After clamping the contacts, push them into the proper holes in the connector housing until they snap in place.

CONTROL

 

1

Ground

Brown

Up

Wire

2

TXB (RS485)

Red

3

TXA (RS485)

Orange

 

 

 

 

4

RXB (RS485)

Yellow

5

RXB (RS485)

Green

 

 

 

 

ALARM IN (8-pin)

 

 

 

 

1

Alarm In 1

Black

2

Ground

Brown

3

Alarm In 2

Red

4

Ground

Orange

5

Alarm In 3

Yellow

6

Ground

Light blue or green

7

Alarm In 4

Blue

8

Ground

Purple

 

 

 

ALARM OUT (4-pin)

 

 

 

 

1

Alarm Out 1

Gray

2

Ground

White

3

Alarm Out 2

Pink

4

Ground

Yellow, Green, or Light blue

 

 

 

 

Caution: For lightning protection of the camera and heater/blower, the pin 3 of the connector must be connected to real electrical ground.

Contact

CAUTIONS

Shrinking the cable-entry seal is a onetime procedure. Do not shrink the cable-entry seal until it has been determined that the unit is functioning.

CONNECT THIS TO A 24 VAC CLASS 2 POWER SUPPLY ONLY.

3

4

4

3

1

 

2

1

2

 

 

 

CAUTION: TO PREVENT FIRE OR SHOCK HAZARD, THE UL-LISTED WIRE VW-1, STYLE 1007, SHOULD BE USED FOR THE CABLE FOR 24 VAC INPUT TERMINALS.

Operating Distances

 

Awg Size

Impedance

Max Distance

 

 

 

Awg #12

1.71 ohm/1000 ft.

440 ft.

 

 

 

Awg #14

2.73 ohm/1000 ft.

270 ft.

 

 

 

Awg #16

4.35 ohm/1000 ft.

170 ft.

 

 

 

Awg #18

6.92 ohm/1000 ft.

100 ft.

 

 

 

 

 

 

- -

Page 4
Image 4
Panasonic Pod9cw WJ-HD316A WU-CU650 Wiring Color Code, Power and Control Inputs, How to assemble the connector, Cautions