Care and Replacement

Removing and replacing the lamp unit

1.Turn the projector upside down and place it gently on a soft cloth.

2.Use a Phillips screw driver to loosen the 2 lamp unit fixing screws until the screws turn freely and remove the lamp unit cover.

3.Use a Phillips screw driver to loosen the 2 lamp unit fixing screws until the screws turn freely.

4.Hold the handle of the lamp unit and pull out gently from the projector.

5.Replace the new lamp unit while making sure that the direction of insertion is correct.

Press the top of the lamp unit and make sure the unit is installed securely.

6.Tighten the lamp unit fixing screws securely with a Phillips screwdriver.

7.Attach the lamp unit cover and tighten the 3 lamp unit cover fixing screws securely with a Phillips screw driver.

Lamp unit cover fixing screws

Lamp unit cover

Lamp unit fixing screws

Press here

Press here

Handle

NOTE:

• Be sure to install the lamp unit and attach the lamp unit cover securely. If they are not installed securely, it may cause the protection circuit to operate so that the power cannot be turned on.

• Grip the handle and keep the lamp unit paralleled when you remove the lamp unit. Some parts of the lamp unit are sharpened and may cause injury.

• Do not switch the power on while the lamp unit cover removed.

Resetting the LAMP RUNTIME

 

If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the

 

 

projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure

 

 

should thus be completed within 10 minutes.

6.

Press and hold the ENTER button for

 

1.

Connect the mains lead to the projector and a

 

 

mains socket, and switch the MAIN POWER on.

 

approximately 3 seconds.

 

2.

Press the POWER button.

7.

The confirmation screen will be displayed and

 

3.

Press the MENU button to display the menu.

 

select OK.

 

4.

Select the OPTION menu and press the ENTER

8.

Press the POWER button to turn off for resetting

 

 

button.

 

the duration of the LAMP RUNTIME.

 

5.

Select LAMP RUNTIME.

9.

Confirm the duration of time in LAMP RUNTIME is

 

 

 

 

 

 

 

 

 

 

 

reset to “0 H”.

Maintenance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH - 43

Page 43
Image 43
Panasonic PT-AX200E manual Care and Replacement Removing and replacing the lamp unit, Resetting the Lamp Runtime