Panasonic PT-D3500E Indication of lamp monitor, Lamp Information Checkpoint Remedial measure

Models: PT-D3500E

1 64
Download 64 pages 21.5 Kb
Page 42
Image 42

Indication of lamp monitor

This projector is equipped with 2 indicators to show when a lamp needs replacement or there is an abnormal internal temperature. These lamps flash or light up to indicate a problem.

Turn the power off and follow the steps below.

Temperature monitor (TEMP) indicator

Lamp monitor (LAMP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name of monitor

 

 

Lamp

 

 

Information

 

 

 

Checkpoint

 

 

Remedial measure

 

 

lamp

 

 

indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you turn on the

 

 

• Wait about five minutes in the

 

 

 

 

 

 

 

 

 

 

 

power when the

 

 

current status.

 

 

 

 

 

 

 

 

Warm-up status

 

 

ambient temperature

 

 

• Install the unit in a location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lighting in

 

 

 

 

 

was low

 

 

having an ambient

 

 

 

 

 

red

 

 

 

 

 

(approx. 0 °C)?

 

 

temperature from 0 to 40 °C.

 

 

 

 

 

(lamp unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Remove the object that is

 

 

 

 

 

ON)

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

High temperature

 

 

• Check if the

 

 

blocking the ventilation port.

 

 

 

 

 

 

 

 

 

 

 

 

 

monitor

 

 

 

 

 

 

 

 

 

• Move the projector to a

 

 

 

 

 

 

 

inside. (WARNING)

 

 

ventilation port is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature of 0 to 40 ˚C and

 

 

 

 

 

 

 

 

 

 

 

blocked.

 

 

 

 

TEMP

 

 

 

 

 

 

 

 

 

 

the humidity of 20 to 80% (no

 

 

 

 

 

 

 

 

 

 

• Is the room air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

condensation).

 

 

 

 

 

 

 

 

 

 

 

temperature too high?

 

 

 

 

 

 

 

Blinking in

 

 

High temperature

 

 

 

 

• Turn off the MAIN POWER

 

 

 

 

 

red

 

 

inside

 

 

• Check the air filter for

 

 

switch using the procedure on

 

 

 

 

 

 

 

 

 

clogging.

 

 

 

 

 

 

 

(2 times)

 

 

(Standby condition)

 

 

 

 

page 23 and clean the air filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(refer to page 43).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking in

 

 

 

 

 

 

 

 

 

 

• Turn off the main power supply

 

 

 

 

 

 

 

Cooling fan has

 

 

 

 

 

 

 

(MAIN POWER) switch in the

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

been stopped.

 

 

 

 

 

 

 

procedure shown on page 23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3 times)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and consult the distributor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you notice a

 

 

• This lamp monitor lights up

 

 

 

 

 

 

 

 

 

 

 

“REPLACE THE

 

 

when the lamp unit used hours

 

 

 

 

 

Lighting in

 

 

Indicates the time

 

 

LAMP” message on

 

 

have reached 1 300 hours

 

 

 

 

 

 

 

for replacing the

 

 

the screen when

 

 

(3 800 hours when long life

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

lamp unit.

 

 

turning on the

 

 

lamp units are used). Request

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp monitor

 

 

 

 

 

 

 

 

projector power

 

 

the dealer to replace the lamp

 

 

 

 

 

 

 

 

 

 

supply?

 

 

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

 

 

• Did you turn the power

 

 

• Wait until the lamp has cooled

 

 

 

 

 

 

 

 

 

 

back on immediately

 

 

off, and then turn on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

after turning it off?

 

 

power.

 

 

 

 

 

Blinking in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error is detected in

 

 

• Some error has

 

 

 

 

 

 

 

 

red

 

 

 

 

arisen in the lamp

 

 

• Turn off the MAIN POWER

 

 

 

 

 

 

 

the lamp circuit.

 

 

 

 

 

 

 

 

 

(3 times)

 

 

 

 

circuit.

 

 

switch using the procedure on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check for fluctuation

 

 

page 23 and consult the

 

 

 

 

 

 

 

 

 

 

 

(or drop) in the source

 

 

dealer.

 

 

 

 

 

 

 

 

 

 

 

voltage.

 

 

 

 

Attention • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps on pages 22, 23.

If the power indicator blinks in red (3 times), the projector has malfunctioned. Please consult your dealer.