![](/images/new-backgrounds/1264027/264027111x1.webp)
Using the PJLink™ protocol
The network functions of the projector are compatible with PJLink™ Class 1. The operations mentioned below can be performed from a personal computer using the PJLink™ protocol.
•Projector settings
•Projector status inquiry
Supported commands
The commands for controlling the projector using the PJLink™ protocol are as given in the table below.
Command | Control Description |
|
| Remarks | |
|
| Parameter | |||
POWR | Power control | 0 = Standby | |||
|
| 1 = Power “ON” | |||
|
| Parameter | |||
|
| 0 = Standby | |||
POWR ? | Power status inquiry | 1 = Power “ON” | |||
|
| 2 = Cooling down | |||
|
| 3 = During | |||
|
| Parameter | |||
INPT | Input selection | 11 | = RGB1 | ||
|
| 12 | = RGB2 | ||
|
| 21 | = VIDEO | ||
INPT ? | Input selection inquiry | 22 | = | ||
|
| 31 | = DVI |
| |
|
| Parameter | |||
AVMT | Shutter control | 10 | = Mute reset of video only | ||
11 | = Mute video | ||||
|
| ||||
|
| 20 | = Mute reset of audio only | ||
|
| ||||
|
| 21 | = Mute audio | ||
AVMT ? | Shutter status inquiry | 30 | = Shutter mode OFF (Mute reset of video and audio) | ||
|
| 31 | = Shutter mode ON (Mute video and audio) | ||
|
|
| |||
|
| Parameter | |||
|
| 1st byte: Refers to fan error; one of 0 to 2 | |||
|
| 2nd byte: Refers to lamp error; one of 0 to 2 | |||
|
| 3rd byte: Refers to temperature error; one of 0 to 2 | |||
ERST ? | Error status inquiry | 4th byte: | 0 fixed | ||
5th byte: | 0 fixed | ||||
|
| ||||
|
| 6th byte: Refers to some other error; one of 0 to 2 | |||
|
| The meaning of 0 to 2 is as given below. | |||
|
| 0 = Error not detected 1 = Warning 2 = Error | |||
|
|
| |||
|
| Parameter | |||
LAMP ? | Lamp status inquiry | First number (digits 1 to 5): Lamp cumulative time | |||
|
| Second number: 0 = Lamp OFF; 1 = Lamp ON | |||
|
|
| |||
INST ? | Input selection list inquiry | Parameter responds with following values: | |||
“11 12 21 22 31” | |||||
|
| ||||
|
|
| |||
NAME ? | Projector name inquiry | Responds with the name set in “HOST NAME” of “NETWORK” | |||
INF1 ? | Manufacturer's name inquiry | Responds with “Panasonic” | |||
INF2 ? | Model name inquiry | Responds with “D3500” | |||
INFO ? | Other information inquiry | Responds with version number and so on | |||
CLSS ? | Class information inquiry | Responds with “1” |
PJLink™ security authentication
The password used in PJLink™ is the same as the password set in the Web Browser Control. To use PJLink™ without authentication, do not set any password in Web Browser Control.
PJLink™ is the
56