-38-
Optical Adjustments
[Before Adjustment]
- Input a 0% of black raster signal.
1 Loosen 3 screws-A (Fig.1) on the polarized glass mounting base.
2 Adjust the slot B to obtain the darkest brightness on the screen by
using a slot screwdriver.
3 Tighten the 3 screws-A to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
-This adjustment should be taken in order of G-panel, R-panel and
B-panel.
-This adjustment should be performed in the darkest room to
improve the precision of adjustment.

Contrast adjustment

Before taking optical adjustments below, remove the cabinet top following to the “Mechanical Disassembly”.
Adjustments require a 2.0mm hex wrench and a slot screwdriver.
Note: Do not disconnect connectors on the MAIN board, because the projector cannot turn on due to operate the
power failure protection.

A

Slot B
Fig.1
WARNING : USE UV RADIATION EYE AND SKIN PRO-
TECTION DURING SERVICING
CAUTION: To prevent suffer of UV radiation, those
adjustment must be completed within 25
minutes.