-56-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
0Mode
IRIS control mode setting
0:APL control by the user menu
1:Fixed control
2:Off control
3:Life Test mode
0 0-3
1Error Detect Enable Iris abnormality detection function 1 0-1 0:Enable, 1:Disable
2Open Position Offset Open Position Offset -12 -511-511
3Speed adjust switch speed setting 4/2 1-1023 AV/PC
4Manual position adjust Iris(off) position setting 0 0-1023
5APL Threshold Min APL Threshold Min data 0/4 0-255 AV/PC
6APL Threshold Max APL Threshold Max data 128/12 0-255 AV/PC
7Change APL Change APL 128/8 0-255 AV/PC
8Change position Change position 0/520 0-1023 AV/PC
9Speed adjust 2 close speed setting 4/2 1-1023 AV/PC
10 Close Limit Dimmer 0 Close Limit Dimmer 0 500/700 0-1023
11 Close Limit Dimmer 1 Close Limit Dimmer 1 500/700 0-1023
12 Close Limit Dimmer 2 Close Limit Dimmer 2 500/700 0-1023
13 Close Limit Dimmer 3 Close Limit Dimmer 3 500/700 0-1023
14 Close Limit Dimmer 4 Close Limit Dimmer 4 500/700 0-1023
15 Close Limit Dimmer 5 Close Limit Dimmer 5 500/700 0-1023
16 Close Limit Dimmer 6 Close Limit Dimmer 6 500/700 0-1023
17 Close Limit Dimmer 7 Close Limit Dimmer 7 500/700 0-1023
18 Close Limit Dimmer 8 Close Limit Dimmer 8 500/700 0-1023
19 Close Limit Dimmer 9 Close Limit Dimmer 9 500/700 0-1023
20 Close Limit Dimmer 10 Close Limit Dimmer 10 500/700 0-1023
21 Close Limit Dimmer 11 Close Limit Dimmer 11 500/700 0-1023
22 Close Limit Dimmer 12 Close Limit Dimmer 12 500/700 0-1023
23 Close Limit Dimmer 13 Close Limit Dimmer 13 500/700 0-1023
24 Close Limit Dimmer 14 Close Limit Dimmer 14 500/700 0-1023
25 Close Limit Dimmer 15 Close Limit Dimmer 15-18 500/700 0-1023
30 Update Interval 1 Update interval 1(unit:ms) 8/15 0-1023 AV/PC
31 Update Interval 2 Update interval 2(unit:ms) 8/1 0-1023 AV/PC
Group
230 VBI Slice Level
0 Generic Initial Slicing Level PW190 register 0xE344 50 0-255
1
Generic High Level Threshold
PW190 register 0xE345 -0-255 * Read only
2
Generic Low Level Threshold
PW190 register 0xE346 -0-255 * Read only
3
Generic Minimum Low Level
PW190 register 0xE347 30 0-255
4 Generic Maximum High Level PW190 register 0xE348 200 0-255
Group
250
FAN Control * Fan vollt-
age adjustment
0FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
36 0-255
1FAN1 MAX ADJUST (DAC) 220 0-255
2FAN2 MIN ADJUST (DAC) 15 0-255
3FAN2 MAX ADJUST (DAC) 210 0-255
4FAN3 MIN ADJUST (DAC) 15 0-255
5FAN3 MAX ADJUST (DAC) 210 0-255
6FAN1 MIN ADJUST (DAC) 36 0-255
7FAN1 MAX ADJUST (DAC) 220 0-255
8FAN2 MIN ADJUST (DAC) 36 0-255
9FAN2 MAX ADJUST (DAC) 220 0-255
10 FAN3 MIN ADJUST (DAC) 56 0-255
11 FAN3 MAX ADJUST (DAC) 220 0-255
12 FAN3 MIN ADJUST (DAC) 56 0-255
13 FAN3 MAX ADJUST (DAC) 220 0-255