-59-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
1 Dimmer Average Dimmer Average Value (Read only) -
2 Last Voltage Difference -
3 Voltage Difference Goal -
Group
258
Colser IRIS,Fan Vlotage
rising
0Fan Vol. Offset Iris
Threshold Fan vol rising to Iris 530 0-1023
1 Fan Vol. Offset Speed Fan vol is set to 1/5 6 0-30
2 Normal Fan4 Offset Lamp mode normal,fan vol. offset
data
10 0-255
3 Normal Fan7 Offset 0 0-255
4 Eco Fan4 Offset Lamp mode Eco,fan vol. offset data 10 0-255
5 Eco Fan7 Offset 0 0-255
Group
259 Fan MIC IC temperature rising resolve
0 Fan6 Fan voltage (unit: 0.1V) 60 0-255
1 Fan7 60 0-255
Group
260 Auto Calibration(Common1*Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when
changiing the Value (PC White
100%)
1 Loop Count Maximum Execution Times (OFFSET-
>GAIN) 10 1 - 30
2 Auto Status Result of Auto-Calibration (Last
Memory) 0 0 / 1 / 9 0: OK, 1: Adjusting,9: Error *
ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group
261 Auto Calibration (RGB1
0 OFFSET AREA H START Black Level Acquiring Area H-Start
Position 975 0 - 1000
1 OFFSET AREA V START Black Level Acquiring Area V-Start
Position 500 0 - 1000
2 GAIN AREA H START White Level Acquiring Area H-Start
Position 25 0 - 1000
3 GAIN AREA V START White Level Acquiring Area V-Start
Position 500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT Black/White Level Acquiring Area
Height 9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1-255
Group
262 Auto Calibration (CVBS/SVIDEO1
0Y Image Area Start X Y Acquiring Area H-Start Position 20 0-1000
1Y Image Area Start Y Y Acquiring Area V-Start Position 200 0-1000
6 Image Area H Width Image Level Acquiring Area 8 0-4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0-4095
8Y Target Level Target Value of Y Level Adj. 217 0-255
11 Gain Tolerance Torelance of Level Adj. 1 0-255
12 Delta Gain Deviation Width of Gain Value 9 0-255
Group
264 Auto Calibration (YCbCr1
0Y-OFFSET AREA H START Y - Offset Acquiring Area H-Start
Position 925 0 - 1000
1Y-OFFSET AREA V START Y - Offset Acquiring Area V-Start
Position 500 0 - 1000
2CB - OFFSET AREA H
START
CB - Offset Acquiring Area H-Start
Position 925 0 - 1000
3CB - OFFSET AREA V
START
CB - Offset Acquiring Area V-Start
Position 500 0 - 1000
4CR - OFFSET AREA H
START
CR - Offset Acquiring Area H-Start
Position 925 0 - 1000
5CR - OFFSET AREA V
START
CR - Offset Acquiring Area V-Start
Position 500 0 - 1000
6Y - GAIN AREA H START 50 0 - 1000
7Y - GAIN AREA V START 500 0 - 1000
8 CB - GAIN AREA H START 800 0 - 1000
9 CB - GAIN AREA V START 500 0 - 1000
10 CR - GAIN AREA H START 700 0 - 1000