1.Human body grounding

4.2. Grounding for electrostatic breakdown prevention

1.Human body grounding

Use the anti-static wrist strap to discharge the static electricity from your body. (as shown in Fig. 3 )

2.Work table grounding

Put a conductive material (sheet) or steel sheet on the area where the optical magnetism head unit is placed, and ground the sheet. (as shown in Fig. 4 )

Caution

The static electricity of your clothes will not be grounded through the wrist strap.

So, take care not to let your clothes touch the optical magnetism head unit.

Fig. 3

Fig. 4