Options Adjustments

Options

2/3

Off-timer function

Enable

 

 

 

 

Initial Power Mode

Normal

 

 

 

 

ID select

0

 

 

 

 

Remote ID

Off

 

 

 

 

Serial ID

Off

 

 

 

 

Display size

Off

 

 

 

 

Studio W/B

Off

 

 

 

 

Studio Gain

Off

Item

Effect

 

 

 

 

 

 

Adjustments

Off-timer

 

 

Enable: Enables the “Off-timer function”.

 

 

Disable:Disables the “Off-timer function”.

function

Enable

Disable

Note: When “Disable” is set, the Off-timer is cancelled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

Standby

On

 

 

 

Sets the power mode of the unit for when the power recovers from failure or after plugging off

 

 

 

and in again.

 

 

 

 

 

Initial Power

 

 

Normal: Power returns in as the same state as before the power interruption.

Mode

 

 

Standby:Power returns in standby mode. (Power Indicator : red/orange)

 

 

 

On:

Power returns in power On. (Power Indicator : green)

 

 

 

Note: When using multiple displays, “Standby” is preferred to be set in order to reduce a power

 

 

 

 

load.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets panel ID number when panel is used in “Remote ID” or “Serial ID”.

ID select

 

 

Set value range: 0 - 100

 

 

 

 

 

 

 

 

(Standard value: 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote ID

 

 

Off: Disables ID remote control functions. You can use normal remote control operations.

Off

On

On: Enable ID remote control functions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets the panel ID Control.

 

 

 

 

 

Serial ID

Off

On

Off: Disables external control by the ID.

 

On: Enables the external control by the ID.

 

 

 

Adjusts the image display size on screen.

 

 

 

Off: Sets the normal image display size on screen.

 

 

 

On: Sets the image display size approximately 95 % of the normal image display.

 

 

 

 

 

Off

 

 

On

Display size

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

• This setting is valid only when the input signals are as follows;

 

 

 

 

NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD))

 

 

 

525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p,

 

 

 

1125/30p, 1125/60p·50p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI)

This setting is invalid when two screen display, digital zoom, Multi display or Portrait display is selected.

When “Display size” is set to “On”, “H-Pos” and “V-Pos” in “Pos. /Size” can be adjusted.

Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals.

 

 

 

Off: Nullify all the settings adjusted.

Studio W/B

Off

On

On: Sets the colour temperature for TV studio.

 

Note: Valid only when the low is set as colour temperature on screen adjustment.

 

 

 

Sharpens the contrast for a better view when a part of the image is too light to see.

 

 

 

Off: Disables “Studio Gain”.

Studio Gain

Off

On

On: Enables “Studio Gain”.

 

Note: This setting is valid only when the input signals are as follows:

 

 

 

Component Video, RGB (analog), SDI, HDMI