Introduction and Installation
Before installation
To avoid malfunction or communication disturbances, do not install the door station in the following locations:
–Places where vibration or any other kind of impact occurs.
–Places where echoing is frequent.
–Places where a high concentration of dust, hydrogen sulfide, phosphorus, ammonia, sulfur, carbon, acid, or noxious fumes occur.
–Within 2 m (6'7") of a TV, microwave, personal computer, air conditioner or any other electrical device.
Standard installation position of the door station and camera range
Upper/lower range | Left/right range |
L Side view of when the camera is facing the front at 0°.
L Top view of when the camera is facing the front at 0°.
|
|
|
| Image range: | |
Center of the |
| Image range: |
| 580 mm (2213/16") | |
door station | 46° |
|
|
| |
| 425 mm (163/4") | L |
|
| |
|
|
|
| ||
|
|
|
| 500 mm | 60° |
|
|
| R | (1911/16") |
|
1450 mm |
|
|
|
|
|
(571/16") | 500 mm |
| L Top view of when the camera is facing the | ||
| (1911/16") |
| left at 15°. |
|
|
|
|
|
|
| Image range: |
|
|
|
|
| 650 mm (259/16") |
|
|
| L |
|
|
|
|
| R |
|
|
|
|
| L Top view of when the camera is facing the | ||
|
|
| right at 15°. |
|
Image range:
650 mm (259/16")
L
R
7