When ON is selected for SUPER-D, the SENS UP SELECT function for the WV-CU254 or WV-CU300 system controller does not work.

Use the buttons on the side of the camera for setup.

While the SENS UP function is selected, noise or spots may appear in the picture when the sensitivi- ty of the camera is increased. This is a normal phenomenon.

6.Synchronization Setting (SYNC)

You can select internal sync mode (INT) or line-lock mode (LL). Additionally, this model accepts VS signal (B/W composite video or composite sync signal). The VD2 signal (multiplexed vertical drive signal) with the composite video output signal from external equipment such as a Matrix Switcher is also acceptable.

Whenever the VD2 signal is supplied to this camera, the camera automatically switches to the VD2 sync mode.

1.Move the cursor to the SYNC parameter and select line-lock(LL) or internal(INT).

2.Press .

If LL is selected, the SYNC menu appears. (If INT is selected, the synchronization mode is automati- cally set to internal sync pulse, and the menu is not displayed.)

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

---

 

AGC

 

ON

 

SENS

UP

OFF

 

SYNC

 

INT

 

MOTION DET

OFF

LENS

DRIVE

DC

 

END

SET UP ENABLE

Important Notices:

1.The priority for the sync modes is as follows.

1.Multiplexed Vertical Drive (VD2) (Highest pri- ority)

2.Line-lock (LL)

3.B/W Composite Video or Composite Sync Signal (VS)

4.Internal Sync (INT) (Lowest priority)

2.When the internal sync mode is to be used, select INT. No gen-lock input signal should be supplied to the Gen-lock Input Connector on the rear panel.

3.Whenever the multiplexed vertical drive pulse (VD2) is supplied to the camera from an external equipment such as a Matrix Switcher, the camera sync mode is automatically switched to the VD2 mode.

4.When the VS gen-lock mode is to be used select INT from this menu and supply the gen-lock input signal to the Gen-lock Input Connector on the rear panel.

-25-