Precautions for installation
Panasonic assumes no responsibility for injuries or property damage resulting from failures arising out of improper installation or operation inconsistent with this documentation.
Power supply
This product has no power switch. Use a power supply device equipped with the
Before cleaning the product, make sure that the power cable is not connected to the main power supply.
Installation area for this product
Select an appropriate place for the installation area (such as a strong wall or ceiling) in your particular environment.
Mounting method for this product
•This product is designed to be used as a pendant mount camera. If the product is mounted on a desk- top or at a slant, it may not work correctly or its life- time may be shorten.
•Mount the product horizontally so that the dome sec- tion faces downward.
Ceiling pendant type mount bracket/Wall mount bracket
•When
•When installing on a wall, use Wall Mount Bracket
<Installing conditions>
Camera |
|
Weight | Approx. 4.6 kg {10.15 lbs} |
Appropriate mount bracket | |
Model No. | |
Weight | Approx. 2 kg {4.42 lbs} |
Mount type | On wall |
Part to be mounted on a ceiling/wall | |
Recommended screw | M8 |
Number of screw | 4 |
823 N {84 lbf} | |
single screw |
|
•Ensure that the mounting surface, anchor and screws are sufficiently strong.
•Do not mount the product on a plaster board or a wooden section because they are too weak. If the product is unavoidably mounted on such a section, the section shall be sufficiently reinforced.
Do not place this product in the following places:
•Locations where a chemical agent is used such as a swimming pool
•Locations subject to humidity, dust, steam and oil smoke
•Locations where a radiation, an
•Locations where corrosive gas is produced, locations where it may be damaged by briny air such as sea- shores
•Locations where the temperature is not within the specified range (☞ page 36).
•Locations subject to vibrations (This product is not designed for
•Locations subject to condensation as the result of severe changes in temperature (In case of installing the product in such locations, the dome cover may become foggy or condensation may be caused on the cover.)
Screw tightening
•The screws and bolts must be tightened with an appropriate tightening torque according to the materi- al and strength of the installation area.
•Do not use an impact driver. Use of an impact driver may damage the screws or cause tightening exces- sively.
•When a screw is tightened, make the screw at a right angle to the surface. After tightening the screws or bolts, perform visual check to ensure tightening is enough and there is no backlash.
Remove the cover film from the dome section of the dome cover after the installation is complete.
Be sure to remove this product if it is not in use.
When noise disturbance may happen
Conduct the power distribution work to keep a distance of 1 m {3.28 feet} or more from the 120 V (for U.S. and Canada) or 220 V - 240 V (for Europe and other countries) power line. Or conduct the electric conduit work sepa- rately.
12