ACCULINK 3163 DSU/CSU
G-14 March 1999 3163-A2-GB20-10
Sync Data Port Options (Port 1) Front Panel
Equivalent Value (Default in Bold)
Port Type Port Type E530, V.35, RS449, X.21
Port Base Rate Base Rate Nx64, Nx56
Transmit Clock Source Tx Clock Internal, External
Invert Transmit Clock InvertTxC Enable, Disable
Invert Transmit and Received Data InvrtData Enable, Disable
Send All Ones on Data Port Not Ready All Ones Disable, DTR, RTS, Both
Action on Network Yellow Alarm Rcv Yellow None, Halt
Network Init. Data Channel Loopback Net DCLB Disable, V.54, FT1, Both
Port (DTE) Initiated Loopbacks Port LB Disable, DTLB, DCLB, Both
General Options Front Panel
Equivalent Value (Default in Bold)
Generate Yellow Alarm Signals Gen Yellow Enable, Disable
Initial Self Test Self-Test Enable, Disable
Primary Clock Source Clock Src Network, DTE, Internal, External, Port 1
External Clock Rate (KHz) Clock Rate 2048, 1544, 8
Test Timeout Tst Timeout Enable, Disable
Test Duration Tst Duration 1 –120 (Default = 10)
User Interface:
Front Panel Options Front Panel
Equivalent Value (Default in Bold)
Front Panel Access FP Access Enable, Disable
Front Panel Pass-Through FP Pass Enable, Disable