ACCULINK 3163 DSU/CSU
3-10 March 1999 3163-A2-GB20-10
The configuration options are divided into functional
groups. Appendix C contains a list of the configuration
options and defaults. These groups are:
Port
Network Interface
Channel
General
User Interface
Alarm
Management
The DSU/CSU arrives with two preset factory default
configuration settings. These settings are based on the
following:
Factory 1 – ESF framing format with B8ZS line
coding format for the network interface. The data
port is unassigned.
Factory 2 – D4 framing format with AMI line
coding format for the network interface. The data
port is unassigned.
If neither of the factory default settings support your
network’s configuration, you can customize the
configuration options to better suit your application.
Use the Configuration (Cnfig) branch of the front panel
menu tree to display or change DSU/CSU configuration
options (see Appendix C, Configuration Options).
Displaying/Editing Configuration Options
"Procedure
To display/edit configuration options:
1. From the top-level menu screen, select Cnfig.
F1
DSU ESF
Stat Test Cnfig
F2 F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
F1
Load from:
Activ Cust1
F2 F3
3. Select Edit.
F1
Choose Funct:
Edit Save
F2 F3