Paradyne 3174, 3172 manual Port Configuration Options 1 Factory Comments/Description, HDB3

Models: 3174 3172

1 20
Download 20 pages 23.29 Kb
Page 7
Image 7

Factory default configuration options are shown in boldface type in the following tables.

Table 1. DTE Interface Configuration Options

Option

Factory

Comments/Description

 

 

 

DTE Port:

Enab

Enables the use of the DTE Drop/Insert port.

 

 

 

 

Disab

 

 

 

 

DTE Frame:

CRC4

Selects framing format.

 

 

 

 

noCRC

 

 

 

 

DTE Coding:

AMI

Selects line coding format.

 

 

 

 

HDB3

 

 

 

 

Extrn DLB:

Enab

Allows control of DLB on external contact

(External DTE

 

closure.

Disab

Loopback)

 

 

 

 

Send Ones:

Enab

Sends all ones on channels allocated to the

 

 

network E1 on LOS, LOF, or AIS.

 

Disab

 

 

 

 

 

Table 2. Port Configuration Options (1 of 3)

Option

Factory

Comments/Description

 

 

 

Port Type:

E530

Selects the port type: EIA-530A, V.35, RS449,

 

 

or X.21.

 

V.35

 

 

 

 

 

 

RS449

 

 

 

 

 

X.21

 

 

 

 

Base Rate:

Nx64

Enables the port to either Nx56 or Nx64 rates.

 

 

 

 

Nx56

 

 

 

 

Net DCLB:

Enab

Network-initiated DCLB, allows DCLB to be

 

 

controlled by inband V.54 codes.

 

Disab

 

 

 

 

 

5

Page 7
Image 7
Paradyne 3174, 3172 manual Port Configuration Options 1 Factory Comments/Description, HDB3