The Hotwire 5620 RTU connects to the local loop via wiring from the demarcation point to an RJ11 wall jack. The DSL twisted-pair wiring from the local loop terminates at a new or existing wall jack. It may be necessary to install a standard single RJ11 jack or replace a single jack with a double RJ11 jack.

Demarcation Point

Central

Office

POTS/DSL

Local Loop

Punchdown

Block or NID

Customer Premises

DSL

Twisted-pair

Wiring

DSL

RJ11

Jack

RTU

97-15343-02

"Procedure

1.Wiring can be run from the punchdown block or NID to a new or existing wall jack. Match the pair colors on both ends.

2.Label the DSL jack.

3.Reconnect the DSL access pair at the punchdown block or NID. Tighten both terminal screws with a flat-blade screwdriver.

RJ11 Wall Jack

or

97-15300a

The RJ11 6-pin jack uses the center two pins. For pin assignments, refer to Cables & Connectors, page 14.