Important Information

Important Safety Instructions

1.Read and follow all warning notices and instructions marked on the product or included in the manual.

2.Input power to this product must be provided by one of the following: (1) a UL Listed/CSA Certified power source with a Class 2 or Limited Power Source (LPS) output for use in North America; or (2) a 24 Vdc National Electric Code (NEC) ANSI/NFPA 70/Canadian Electric Code (CEC) Class 2 circuit installed in accordance with articles 110-16, 110-17, and 110-18 of the NEC, and articles 2-308, 2-310, 2-312, 2-314, 2-200, and 2-202 of the CEC, or

(3)a Safety Extra Low Voltage (SELV) power source with a maximum available output of less than 240 VA, certified for use in the country of installation.

3.Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.

4.Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.

5.Do not attempt to install or service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all installation and servicing to qualified service personnel.

6.General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.

7.When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.

8.A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.

9.In addition, if the equipment is to be used with telecommunications circuits, take the following precautions: Ð Never install telephone wiring during a lightning storm.

Ð Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Ð Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Ð Use caution when installing or modifying telephone lines.

Ð Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

Ð Do not use the telephone to report a gas leak in the vicinity of the leak.

7975-A2-GB20-40

December 1998

B

Page 3
Image 3
Paradyne 7975 manual Important Safety Instructions

7975 specifications

The Paradyne 7975 is a robust and versatile product that has made significant strides in the realm of data communications. This device primarily facilitates high-speed data transmission, leveraging advanced technologies designed to optimize performance and reliability. One of its standout features is its ability to handle both analog and digital signals, making it an essential tool for various networking environments.

One of the key technologies employed in the Paradyne 7975 is the use of digital signal processing (DSP). This technology enhances the quality of signals transmitted over long distances, reducing the impact of noise and other interferences that can degrade performance. The integration of DSP allows for improved error correction techniques, ensuring data integrity during transmission.

Another notable feature of the Paradyne 7975 is its compatibility with a range of communication protocols. This inclusivity allows users to connect the device seamlessly with existing infrastructure, facilitating a smooth transition to higher data rates without the need for extensive upgrades. The product supports both T1 and E1 lines, catering to various network structures and requirements.

In terms of performance, the Paradyne 7975 boasts data rates of up to 2.048 Mbps for E1 and 1.544 Mbps for T1, allowing for efficient bandwidth utilization. Its architecture is designed for scalability, enabling businesses to expand their networks without encountering significant bottlenecks. Additionally, the device features built-in diagnostics and monitoring capabilities, which provide administrators with real-time insights into network performance and health.

The physical design of the Paradyne 7975 is also noteworthy. It typically comes in a compact form factor that can easily fit into standard telecommunications racks, making it a space-saving solution for data centers and offices. Its rugged construction ensures longevity and reliability, even in demanding environments.

Moreover, the device includes an intuitive user interface that simplifies configuration and maintenance processes, reducing the overall burden on IT staff. Additionally, its adaptive capabilities enable the device to automatically adjust to varying line conditions, ensuring optimal performance at all times.

Overall, the Paradyne 7975 stands out as a comprehensive solution for businesses seeking to enhance their data communication infrastructures. With its advanced features, compatibility, and user-friendly design, it continues to be a preferred choice for organizations looking to leverage high-speed data transmission technologies.