Initial Startup and Configuration

Configuring the Unit Using the Internal Switches

Use internal Switchpacks S1 and S2 to manually configure the unit. Use

Figure 3-1 to locate Switchpacks S1 and S2.

!HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES

 

This product is designed to protect sensitive components from damage

 

due to electrostatic discharge (ESD) during normal operation. When

 

performing installation procedures, however, take proper static control

 

precautions to prevent damage to equipment. If you are not sure of the

496-15104

proper static control precautions, contact your nearest sales or service

representative.

 

"Procedure

To configure the unit using internal Switchpacks S1 and S2:

1.Power down the unit and remove the enclosure cover, exposing the circuit board.

2.Locate Switchpack S1 using Figure 3-1.

3.Set switch 1 on Switchpack S1 to ON to enable Switchpacks 1 and 2.

4.After you enable the switchpacks, you must set the switches to your desired configuration. Refer to Figure 3-1and Table 3-1.

5.Replace and secure the cover.

6.Power up the board to reset and enable the new configuration.

3-6

December 1998

7975-A2-GB20-40

Page 32
Image 32
Paradyne 7975 manual Configuring the Unit Using the Internal Switches, Handling Precautions for STATIC-SENSITIVE Devices

7975 specifications

The Paradyne 7975 is a robust and versatile product that has made significant strides in the realm of data communications. This device primarily facilitates high-speed data transmission, leveraging advanced technologies designed to optimize performance and reliability. One of its standout features is its ability to handle both analog and digital signals, making it an essential tool for various networking environments.

One of the key technologies employed in the Paradyne 7975 is the use of digital signal processing (DSP). This technology enhances the quality of signals transmitted over long distances, reducing the impact of noise and other interferences that can degrade performance. The integration of DSP allows for improved error correction techniques, ensuring data integrity during transmission.

Another notable feature of the Paradyne 7975 is its compatibility with a range of communication protocols. This inclusivity allows users to connect the device seamlessly with existing infrastructure, facilitating a smooth transition to higher data rates without the need for extensive upgrades. The product supports both T1 and E1 lines, catering to various network structures and requirements.

In terms of performance, the Paradyne 7975 boasts data rates of up to 2.048 Mbps for E1 and 1.544 Mbps for T1, allowing for efficient bandwidth utilization. Its architecture is designed for scalability, enabling businesses to expand their networks without encountering significant bottlenecks. Additionally, the device features built-in diagnostics and monitoring capabilities, which provide administrators with real-time insights into network performance and health.

The physical design of the Paradyne 7975 is also noteworthy. It typically comes in a compact form factor that can easily fit into standard telecommunications racks, making it a space-saving solution for data centers and offices. Its rugged construction ensures longevity and reliability, even in demanding environments.

Moreover, the device includes an intuitive user interface that simplifies configuration and maintenance processes, reducing the overall burden on IT staff. Additionally, its adaptive capabilities enable the device to automatically adjust to varying line conditions, ensuring optimal performance at all times.

Overall, the Paradyne 7975 stands out as a comprehensive solution for businesses seeking to enhance their data communication infrastructures. With its advanced features, compatibility, and user-friendly design, it continues to be a preferred choice for organizations looking to leverage high-speed data transmission technologies.