5. Diagnostics
5-10 February 2003 8335-A2-GB20-70
Card Alarms Screen – Model 8385

(Continued)

D-B
Minor Alarms:
Config Error – If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.
Loss of Cell Delineation – If a loss of cell delineation has been detected on the port, an
A (for Alarm) appears in the column for that port.
Loss of Signal – If a loss of signal has been detected on the port, an A (for Alarm)
appears in the column for that port.
Error Seconds –The number of Errored Seconds has exceeded the user-defined
threshold.
Severely Errored Seconds – The number of Severely Errored Seconds has exceeded
the user-defined threshold.
Unavailable Seconds – The number of Unavailable Seconds has exceeded the
user-defined threshold.
Loss of Sync Word Second – The number of Loss of Sync Word (LOSW) seconds has
exceeded the user-defined threshold.
CRC Anomalies Threshold – The number of CRC anomalies has exceeded the
user-defined threshold.
SNR Margin Threshold – The SNR margin has exceeded the user-defined threshold.
Attenuation Threshold – The current value reached or dropped below the user-defined
threshold.
Repeater Segment Down – One of the repeater segments is down.
SN Loss of Power – The endpoint has lost power.
CAC Exceeded – The DSL line rate has dropped below the traffic contract. The traffic
contract has exceeded the available bandwidth making the contract invalid.

Table 5-2. Monitoring – Card Alarms (6 of 6)